HRC Instrument Timeline

The following timeline documents changes affecting the HRC to the CIAO software (denoted SW), calibration products in the CALDB (denoted CAL), standard data processing done in the pipeline (denoted SDP), and instrument settings (denoted INS).

Jump to year:20092008200720062005200420032002200120001999

Date HRC-I Event HRC-S Event
January 21, 2009
(CALDB 4.4.1 release)
CAL Version 8 of HRMA Effective Area released in CALDB 4.4.1
September 13, 2007
(CALDB 3.4.1 release)
CAL Version 3 of degap look-up table released in CALDB 3.4.1
May 16, 2007
(CALDB 3.4.0 release)
CAL Version 2 of time-dependent gain correction maps released in CALDB 3.4.0 CAL Version 9 of QE released in CALDB 3.4.0
December 18, 2006
(CIAO 3.4 release)
SW Two new tools introduced in CIAO 3.4: hrc_build_badpix, for creating an observation-specific bad pixel file for HRC data, and hrc_dtfstats, for computing deadtime statistics
December 15, 2006
(CALDB 3.3.0 release)
CAL Version 1 of time-dependent gain correction maps released in CALDB 3.3.0
CAL Version 1 of RMF released in CALDB 3.3.0
August 9, 2006
(CALDB 3.2.3 release)
CAL A corrected Version 1 of the high voltage gain map was installed in CALDB 3.2.3, to be used in place of the version installed on November 16, 2005 in CALDB 3.2.0, which was discovered to be incorrect.

CAL Version 2 of the degap look-up table installed in CALDB 3.2.3

December 15, 2005
(CALDB 3.2.1 release)
CAL Version 1 of the RMF introduced in CALDB 3.2.1 CAL Version 8 of the QE installed in CALDB 3.2.1
CAL Version 7 of HRMA Effective Area released in CALDB 3.2.1
November 16, 2005
(CALDB 3.2.0 release)
CAL Version 1 of the gain maps for the high voltage and current voltage settings introduced in CALDB 3.2.0 CAL Version 2 of the degap look-up table installed in CALDB 3.2.0
June 23, 2005
(CIAO 3.2.2 release)
SW Format of degap correction in hrc_process_events changed from polynomial coefficients to a look-up table
June 14, 2005
(CALDB 3.0.4 release)
CAL Version 1 of the degap look-up table installed in CALDB 3.0.4 CAL Version 1 of the degap look-up table installed in CALDB 3.0.4
February 8, 2005
(CALDB 3.0.1 release)
CAL Version 7 of the QE and Version 4 of the QEU installed in CALDB 3.0.1

August 11, 2004
(CALDB 2.28 release)
CAL Version 3 of the bad pixel map installed in CALDB 2.27
July 7, 2004
(CIAO 3.1 release)
SW Default rand_pix_size set to 0 in hrc_process_events
was: 0.5
July 1, 2004
(CALDB 2.27 release)
CAL Version 3 of GTI limits (for 2002/11/15-Present) installed in CALDB 2.27

CAL Version 6 of GTI limits (for 1999/10/04-2002/11/15) installed in CALDB 2.27

CAL Version 6 of GTI limits (for Launch-1999/10/04) installed in CALDB 2.27

CAL Version 3 of GTI limits (for 2002/11/15-Present) installed in CALDB 2.27

CAL Version 6 of GTI limits (for Launch-2002/11/15) installed in CALDB 2.27

December 15, 2003
(CIAO 3.0.2 release)
CAL Version 7 of mean quantum efficiency model installed in CALDB 2.25
SW Amplifier scale-factor correction in hrc_process_events turned on by default

SW New tap ringing correction algorithm installed in hrc_process_events

October 12, 2003 INS Flight settings changed so that HRC door is no longer closed during radiation passages
September 23, 2003 CAL Version 2 of tap ringing test coefficients installed in CALDB 2.24 CAL Version 2 of tap ringing test coefficients installed in CALDB 2.24

November 29, 2002 CAL Version 1 of GTI limits (for 2002/11/15-Present) installed in CALDB 2.19 CAL Version 1 of GTI limits (for 2002/11/15-Present) installed in CALDB 2.19
November 8, 2002 CAL Version 1 of amplifier scale-factor correction coefficients installed in CALDB 2.18 CAL Version 1 of amplifier scale-factor correction coefficients installed in CALDB 2.18
October 1, 2002 CAL Version 6 of mean quantum efficiency model installed in CALDB 2.17 CAL Version 6 of mean quantum efficiency model installed in CALDB 2.17
August 15, 2002 CAL Version 4 of GTI limits (for 1999/10/04-2002/11/15) installed in CALDB 2.16

CAL Version 4 of GTI limits (for Launch-1999/10/04) installed in CALDB 2.16

CAL Version 4 of GTI limits (for Launch-2002/11/15) installed in CALDB 2.16
July 26, 2002
(Pipeline 6.9 release)
SDP HRC-S bad pixels now identified and handled correctly

SDP 'HRC-SI' no longer used to indicate HRC-S imaging observations -- 'HRC-S' now used for all HRC-S observations (with or without grating)

SDP New HRC mask data product implemented to identify detector active area
June 25, 2002 CAL Version 5 of mean quantum efficiency model installed in CALDB 2.15
April 4, 2002 CAL Version 2 of bad pixel list installed in CALDB 2.13
February 14, 2002 CAL Version 5 of mean quantum efficiency model installed in CALDB 2.12

Version 3 of QE uniformity map installed in CALDB 2.12

January 29, 2002
(Pipeline 6.6 release)
SDP Spurious gaps in Good Time Intervals (GTIs) fixed

December 26, 2001 CAL Version 2 of bad pixel list installed in CALDB 2.11
December 12, 2001 CAL Version 4 of mean quantum efficiency model installed in CALDB 2.10
December 5, 2001
(Pipeline 6.5 release)
SDP If PI value is greater than 255, it is set to 255 and status bit 25 is set
October 22, 2001 CAL Version 2 of QE uniformity map installed in CALDB 2.9 CAL Version 4 of mean quantum efficiency model installed in CALDB 2.9

CAL Version 2 of QE uniformity map installed in CALDB 2.9

June 1, 2001 CAL Version 3 of GTI limits (for 1999/10/04-2002/11/15) installed in CALDB 2.6

CAL Version 3 of GTI limits (for Launch-1999/10/04) installed in CALDB 2.6

CAL Version 3 of GTI limits (for Launch-2002/11/15) installed in CALDB 2.6
May 15, 2001 CAL Version 2 of degap correction table installed in CALDB 2.5
April 24, 2001
(Pipeline 6.0 release)
SDP Bug fix: TLMIN/TLMAX listed in FITS header for HRC-S TDET coordinates are now correct. (They were flipped.)

SDP Events with PHA = 255 now filtered out of level 2 data files

SDP Added support for high precision event timing HRC observations with vetoes disabled
March 19, 2001 CAL Version 2 of event hyperbolic test coefficients installed in CALDB 2.4 CAL Version 2 of event hyperbolic test coefficients installed in CALDB 2.4
March 7, 2001 CAL Version 1 of LETG/HRC-S PI region filters installed in CALDB 2.3
February 20, 2001
(Pipeline R4CU5UPD14.3 release)
SDP Bug fix: Tools using detnam.par parameter files will now use hrc-s.par if detnam = 'HRC-SI'
February 8, 2001
(Pipeline R4CU5UPD14.2 release)
SDP Bug fixed so that CALDB queries for 'HRC-SI' (i.e. HRC-S in imaging mode) will return data for HRC-S
January 25, 2001 CAL Version 2 of degap correction table installed in CALDB 2.2 CAL Version 1 of tap ringing test coefficients installed in CALDB 2.2

December 13, 2000
(Pipeline R4CU5UPD13.1 release)
SDP Bug fix: Update to HRC level 2 status bit filter mask now applied to secondary mode pipelines
December 4, 2000
(CIAO 2.0 release)
SW tgextract modified to accept non-rectangular regions, i.e. the bow-tie shaped extraction region for HRC-S/LETG data

SW Bugs in celldetect which could affect HRC-S data were fixed

SW hrc_process_events CALDB-enabled

SW typo in mkgarf affecting the grating ARF for HRC fixed

November 26, 2000 CAL Version 2 of two-dimensional point spread function models installed in CALDB 2.0 CAL Version 2 of two-dimensional point spread function models installed in CALDB 2.0
November 15, 2000 CAL Version 2 of LETG/HRC-S region filter installed in CALDB 1.8
October 23, 2000
(Pipeline R4CU5UPD11.1 release)
SDP Event status filter modified to ignore value of status bit 12 (as had been done for bit 11 on Sept 27, 2000), and to check that the values of status bits 7 and 8 are clear
October 5, 2000 INS Default commanded event-width threshold changed to 2
was: 3
INS Default commanded event-width threshold changed to 2
was: 3
September 27, 2000
(Pipeline R4CU5UPD10 release)
SDP Event status filter modified to ignore values of status bits 10 and 11. (Note that bit 10 was already ignored.)
August 7, 2000
(Pipeline R4CU5UPD8 release)
SDP Bug fix: due to pixel randomization, the TLMIN/TLMAX limits recorded in the FITS headers for the DET and SKY coordinates should be, respectively, 0.5 pixels smaller/larger. The correct values for are 0.5 to 32768.5 for HRC-I, and 0.5 to 65536.5 for HRC-S.

SDP The following columns are now removed from the level 2 event files: CRSU, CRSV, AMP_SF, AU1, AU2, AU3, AV1, AV2, AV3, RAWX, RAWY, SUMAMPS. They remain in the level 1 event files, but are not appropriate for higher level data products.

July 31, 2000 CAL Version 1 of event hyperbolic test coefficients installed in CALDB 1.3

CAL Version 1 of amplifier saturation test coefficients installed in CALDB 1.3

CAL Version 1 of tap ringing test coefficients installed in CALDB 1.3

CAL Version 1 of event hyperbolic test coefficients installed in CALDB 1.3

CAL Version 1 of amplifier saturation test coefficients installed in CALDB 1.3

CAL Version 1 of detector gain map installed in CALDB 1.3

July 26, 2000
(Pipeline R4CU5UPD7 release)
SDP Updated analysis reference data to provide a calibration of the PI column for HRC-S data. The PI column is a mapping of the observed pulse height corrected for variation of gain across the detector. Prior to this, PI was set to 0 for all HRC data (still true for HRC-I data).
SDP Bug causing the beginning or end of a data interval to be determined incorrectly when the HRC data mode changes between OBSERVING and NEXT_IN_LINE in HRC level 0.5 files fixed

SDP Tap ringing algorithm implemented in pipeline to correct event fine positions

SDP Amplifier saturation test revised to support analysis reference data as a function of amp_sf value

SDP Revised the hyperbolic test algorithm to use lower cutoff for center tap fraction

SDP Corrected several keywords in FITS headers of level 0.5 files

March 26, 2000 CAL Version 2 of GTI limits (for Launch-1999/10/04) installed in CALDB 1.0

CAL Version 2 of GTI limits (for 1999/10/04-2002/11/15) installed in CALDB 1.0

CAL Version 2 of GTI limits (for Launch-2002/11/15) installed in CALDB 1.0
March 6, 2000
(CIAO 1.1.1 release)
SW mkgarf fixed so that it now works correctly for HRC-S data
March 1, 2000 CAL Version 1 of event flatness test coefficients installed in CALDB 1.0 CAL Version 1 of event flatness test coefficients installed in CALDB 1.0

December 21, 1999 CAL Version 3 of mean quantum efficiency model installed in CALDB 1.0

CAL Version 1 of QE uniformity map installed in CALDB 1.0

CAL Version 3 of mean quantum efficiency model installed in CALDB 1.0

CAL Version 1 of QE uniformity map installed in CALDB 1.0

December 16, 1999 SW Initial CIAO release
December 6, 1999 INS Range Switch Level to step 115
was: 90
INS Range Switch Level to step 125
was: 90
November 15, 1999 CAL Version 1 of degap correction table installed in CALDB 1.0 CAL Version 1 of degap correction table installed in CALDB 1.0
October 21, 1999   INS Use edge-blank with u=69-74, v=1-255
was: no-blanking
October 6, 1999 CAL Version 1 of bad pixel list installed in CALDB 1.0
October 4, 1999 INS MCP HV final steps lowered to Top=77, Bot=89
was: Top=79, Bot=91
 
September 13, 1999 CAL Version 1 of bad pixel list installed in CALDB 1.0
September 2, 1999 INS Anti-coincident veto enabled
was: disabled
 
July 23, 1999 Chandra launched