Back to Top

HRCTEMP
Static Version: Mean --- Last One Years

One Week Three Month One Year Five Year Full Range Min Mean Max

Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.

MSID MeanRMSDelta/YrDelta/Yr/YrUnitDescriptionLimit Violation
2ceahvpt 8.190e-055.973e-05(2.79+/-0.01)e20.02 +/- 0.02KCEA RADIATOR TEMPERATURE AT CENTERNo Violation Check
2chtrpzt 1.926e-056.046e-05(2.76+/-0.01)e20.02 +/- 0.02KCENTRAL ELECTRONICS BOX TEMPNo Violation Check
2condmxt -1.534e-048.629e-05(2.72+/-0.02)e20.02 +/- 0.03KCONDUIT -X FACE TEMPERATURENo Violation Check
2dcentrt -2.280e-044.709e-05(2.74+/-0.01)e20.00 +/- 0.01KDETECTOR HOUSING TEMP 2No Violation Check
2dtstatt -6.813e-056.341e-05(2.71+/-0.02)e20.02 +/- 0.02KDETECTOR HOUSING TEMP 1No Violation Check
2fhtrmzt -1.310e-041.126e-04(2.67+/-0.03)e20.03 +/- 0.04KFRONT END ELECTRONICS BOX TEMPERATURENo Violation Check
2fradpyt -2.315e-041.185e-04(2.65+/-0.03)e20.00 +/- 0.04KFRONT END ASSEMBLY +Y AT RADIATOR CENTER TEMPNo Violation Check
2pmt1t -7.417e-048.441e-05(2.85+/-0.02)e20.03 +/- 0.03KPMT 1 TEMPERATURENo Violation Check
2pmt2t -6.078e-048.358e-05(2.85+/-0.02)e20.03 +/- 0.03KPMT 2 TEMPERATURENo Violation Check
2uvlspxt -6.614e-046.149e-05(2.76+/-0.02)e2-0.01 +/- 0.02KUV LIGHT SHIELD NEXT TO SNOUT TEMPNo Violation Check

If you have any questions, please contact swolk@cfa.harvard.edu.

Data Updated: Apr 23, 2026
Last Site Modification: Sep 30, 2021