| One Week | Three Month | One Year | Five Year | Full Range | Min | Mean | Max |
|---|
Delta/Yr below is a slope of the linear fitting over the data of the period. Delta/Yr/Yr is a slope of the liner fitting over the devivative data of the period. Slope listed on a linked plot is the slope computed on the last few periods of the data to show the direction of the trend, and different from that of Delta/Yr.
| MSID | Mean | RMS | Delta/Yr | Delta/Yr/Yr | Unit | Description | Limit Violation | |
|---|---|---|---|---|---|---|---|---|
| 1cbat | -1.239e-04 | 8.700e-04 | (2.11+/-0.02)e2 | -0.44 +/- 0.76 | K | CAMERA BODY TEMP. A | No Violation Check | |
| 1cbbt | -5.718e-04 | 8.637e-04 | (2.12+/-0.02)e2 | -0.30 +/- 0.77 | K | CAMERA BODY TEMP. B | No Violation Check | |
| 1crat | 0.008 | 0.002 | (1.53+/-0.04)e2 | -0.75 +/- 0.87 | K | COLD RADIATOR TEMP. A | No Violation Check | |
| 1crbt | -0.939 | 0.059 | (4.93+/-1.44)e2 | 22.48 +/- 26.90 | K | COLD RADIATOR TEMP. B | No Violation Check | |
| 1dactbt | -0.007 | 0.002 | (2.62+/-0.04)e2 | 0.25 +/- 1.52 | K | DA COLLIMATOR TEMP. B | No Violation Check | |
| 1deamzt | 0.011 | 0.003 | (2.89+/-0.06)e2 | -1.76 +/- 1.13 | K | DEA -Z PANEL TEMP | No Violation Check | |
| 1dpamyt | 0.010 | 0.003 | (2.88+/-0.07)e2 | -1.72 +/- 1.18 | K | DPA -Y PANEL TEMP | No Violation Check | |
| 1dpamzt | 0.011 | 0.003 | (2.91+/-0.06)e2 | -1.72 +/- 1.14 | K | DPA -Z PANEL TEMP | No Violation Check | |
| 1oahat | -0.004 | 0.001 | (2.49+/-0.03)e2 | -0.05 +/- 1.13 | K | OPEN ACTUATOR HOUSING TEMP. A | No Violation Check | |
| 1oahbt | -0.003 | 0.001 | (2.45+/-0.02)e2 | -0.22 +/- 1.05 | K | OPEN ACTUATOR HOUSING TEMP. B | No Violation Check | |
| 1pdeaat | 0.013 | 0.003 | (3.05+/-0.06)e2 | -4.86 +/- 1.66 | K | PSMC DEA PS A TEMP | No Violation Check | |
| 1pdeabt | 0.015 | 0.003 | (2.97+/-0.06)e2 | -4.69 +/- 1.60 | K | PSMC DEA PS B TEMP | No Violation Check | |
| 1pin1at | -0.002 | 0.002 | (3.44+/-0.04)e2 | 0.13 +/- 0.43 | K | PSMC TEMP 1A | No Violation Check | |
| 1wrat | 0.001 | 8.689e-04 | (1.94+/-0.02)e2 | -0.56 +/- 0.59 | K | WARM RADIATOR TEMP. A | No Violation Check | |
| 1wrbt | 0.001 | 8.752e-04 | (1.94+/-0.02)e2 | -0.60 +/- 0.60 | K | WARM RADIATOR TEMP. B | No Violation Check |
If you have any questions, please contact
swolk@cfa.harvard.edu.
Data Updated: Oct 22, 2026
Last Site Modification: Sep 30, 2021