File | $Source: /home/juda/www/hrc_flight/RCS/sh2tosh1.html,v $ |
Version | $Revision: 1.2 $ |
Last Update | $Date: 1999/05/10 17:17:43 $ |
HRC CCB Status | Approved |
OP03 Procedures | op03: |
High-level pulse commands are used to select CEA-A for PMT#1 and CEA-B for PMT#2.
If PMT #1 is intended to be used, its HV power supply must be turned on after the configuration is changed using either sh1_act.html or sh1_on_and_up.html.
Delta-Time | Command Mnemonic | Description | Cmd Field Mnemonic | Data Parameter | Telemetry Verifier | Expected Value | Notes |
---|---|---|---|---|---|---|---|
Verify that both PMT HV power supplies are off | |||||||
00:00:01.000 | 2PRA1SL | Shield PMT#1 select to use CEA A electronics | 2ELEASS | PMT1 | hlp3b | ||
00:00:01.000 | 2PRB2SL | Shield PMT#2 select to use CEA B electronics | 2ELEBSS | PMT2 | hlp7d |
$Log: sh2tosh1.html,v $
Revision 1.2 1999/05/10 17:17:43 juda
changed initial Delta_time to 1 sec - Marked as Approved
Revision 1.1 1999/05/10 12:53:14 juda
Initial revision
Dr. Michael
Juda
Harvard-Smithsonian Center for Astrophysics
60 Garden Street, Mail Stop 70
Cambridge, MA 02138, USA
Ph.: (617) 495-7062
Fax: (617) 495-7356