File | $Source: /home/juda/www/hrc_flight/RCS/power-down.html,v $ |
Version | $Revision: 1.7 $ |
Last Update | $Date: 1999/05/10 18:08:08 $ |
HRC CCB Status | Approved |
OP03 Procedures | op03: |
This sequence uses serial digital commands to shut off each of the HV power supplies, HRC-S, HRC-I, PMT 1, and PMT 2 (only one of HRC-I or HRC-S and one of PMT 1 or PMT 2 should be on). It then sends high level pulse commands to switch off both the A and B side +5V power supplies (again only one of these should be on).
This command sequence is based on the HRC EGSE scripts allhvoff.cmd and 5voff.cmd
Delta-Time | Command Mnemonic | Description | Cmd Field Mnemonic | Data Parameter | Telemetry Verifier | Expected Value | Notes |
---|---|---|---|---|---|---|---|
00:00:01.000 | 2SPHVOF | HRC-S HVPS Off | 2SPONST | OFF | sd0100 | ||
00:00:01.000 | 2IMHVOF | HRC-I HVPS Off | 2IMONST | OFF | sd0900 | ||
00:00:01.000 | 2S1HVOF | Shield PMT#1 HVPS off | 2S1ONST | OFF | sd0500 | ||
00:00:01.000 | 2S2HVOF | Shield PMT#2 HVPS off | 2S2ONST | OFF | sd0d00 | ||
00:00:01.000 | 2SPTTHV | Set HRC-S top MCP HV step to 0 | 2SPTTHV2 | 0 | 2SPTPAST | 0 | sd0200 |
00:00:01.000 | 2SPTBHV | Set HRC-S bottom MCP HV step to 0 | 2SPTBHV2 | 0 | 2SPBPAST | 0 | sd0300 |
00:00:01.000 | 2IMTTHV | Set HRC-I top MCP HV step to 0 | 2IMTTHV2 | 0 | 2IMTPAST | 0 | sd0a00 |
00:00:01.000 | 2IMTBHV | Set HRC-I bottom MCP HV step to 0 | 2IMTBHV2 | 0 | 2IMBPAST | 0 | sd0b00 |
00:00:01.000 | 2S1STHV | Set shield PMT#1 HV step to 0 | 2S1STHV2 | 0 | 2S1HVST | 0 | sd0600 |
00:00:01.000 | 2S2STHV | Set shield PMT#2 HV step to 0 | 2S2STHV2 | 0 | 2S2HVST | 0 | sd0e00 |
00:00:01.000 | 205VAOF | +5V Low Voltage Power Supply Side A Off | 2PS5AON | OFF | hlp3f | ||
00:00:01.000 | 205VBOF | +5V Low Voltage Power Supply Side B Off | 2PS5BON | OFF | hlp7f |
$Log: power-down.html,v $
Revision 1.7 1999/05/10 18:08:08 jhc
corrected initial time delay to 1 sec
Revision 1.6 1998/06/03 21:55:00 juda
corrected delta-time for 205VAOF command (+5V Low Voltage Power Supply Side A Off) from 0 seconds to 1 second
Revision 1.5 1998/05/18 15:53:01 juda
corrected telemetry verifier mnemonics for MCP HV Step commands (2IMTPST -> 2IMTPAST, 2IMBPST -> 2IMBPAST, 2SPTPST -> 2SPTPAST and 2SPBPST -> 2SPBPAST)
Revision 1.4 1998/05/13 16:19:05 juda
Added "File" entry to version table
Revision 1.3 1998/05/06 18:24:18 juda
added the OBC SCS # to the sequence name field
Revision 1.2 1998/05/06 18:14:14 juda
added "to 0" to "Set shield PMT#1 HV step" - marked as approved
Revision 1.1 1998/04/29 19:25:58 juda
Initial revision
Dr. Michael
Juda
Harvard-Smithsonian Center for Astrophysics
60 Garden Street, Mail Stop 70
Cambridge, MA 02138, USA
Ph.: (617) 495-7062
Fax: (617) 495-7356