Step	Title                    	Time	Command     	Command     	Cmd         	Seq         	Telemetry   	Telemetry   	Expected    	Units 	Telemetry   	Other       	Crit        	Description              	Notes       	RT 	Tlm	Min	SIM   
\# 	5.17\_V2.0                         	Req (m)	Description 	Mnemonic    	EGSE        	Key         	Description 	Mnemonic    	Value       	      	EGSE        	Verifier        	              	                         	            	Con	Fmt	Alt	Pos                   	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	      	      
1	Issue Power Command
1.1	Power off FEPs & Video Boards	1	changeConfigSetting	WSPOW00000							Verify cmdResult==1		1			Y	1or2	
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 773 	            	1 	   	   	      	 	 	 
2	Select BEP A
2.1	Select BEP A             	1   	            	1BSELICL(0) 	            	            	            	            	            	      	            	            	            	1BSELICL=0 selects BEP A   	            	Y  	1or2	   	      

3	Cold Boot BEPs
3.1	Set boot modifier off 	1   	DPA Boot Modifier	1BMODIBM(0) 	            	            	            	            	            	      	            	            	            	Disable uplink boot  	   	Y 	1or2 	   	      
3.2	Set warm boot flag off      	1   	DPA Cold Boot	1WRMBTSB(0) 	            	            	            	            	            	      	            	            	            	Cold boot active BEP     	   	Y   	1or2 	   	      
3.3	Halt BEP                 	1   	DPA Command Reset	1RSETIRT(1) 	            	            	            	            	            	      	            	            	            	Hold active BEP reset line	    	Y  	1or2 	   	      
3.4	Restart BEP              	1   	            	1RSETIRT(0) 	            	            	            	            	            	      	            	 	           	Release BEP reset line   	    	Y  	1or2	   	      
3.5 	Check BEP A Boot 	2 	            	            	            	            	            	            	            	     	Check bepStartupMessage:   	            	1   	   	   	 Y   	1or2 	 	 
   	                         	    	            	            	            	            	            	            	            	      	bepTickCounter $<10$; version=11;	            	1  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	warmBootFlag = 0;         	            	1   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	patchValidFlag = 1         	            	1   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	Check swHousekeeping messages:	            	   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	startingBepTickCounter $<10$;            	            	2  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	endingBepTickCounter=  	            	2  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	startingBepTickCounter+640;  	            	  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	version = 11 	            	1 	   	   	      	 	 	 
3.6 	Check HW LEDs    	2  	            	            	            	      	BEP Select 	1STAT4ST    	0          	     	            	            	2 	0 indicates BEP A is selected 	            	 Y 	1or2   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Full 	1STAT6ST    	1          	     	            	            	2 	1 means FIFO not full 	            	   	   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Empty 	1STAT7ST    	0          	     	            	            	2 	0 means FIFO empty 	            	   	   	   	      
3.7 	Check SW LEDs    	2  	            	            	            	      	BEP initialization 	1STAT3ST    	0          	     	            	            	1 	0 means BEP SW is running 	            	 Y  	1or2   	   	      
   	   	    	            	            	            	      	Watchdog boot 	1STAT2ST    	1          	     	            	            	2 	1 means no watchdog boot 	            	   	   	   	      
   	   	    	            	            	            	      	Science run status	1STAT1ST    	1          	     	            	            	2 	1 means science idle 	            	   	   	   	      
   	   	    	            	            	            	      	  	1STAT0ST    	0or1          	     	            	            	2 	This bit toggles to indicate BEP is running

4	Issue Power Command
4.1	Power off FEPs & Video Boards	1	changeConfigSetting	WSPOW00000							Verify cmdResult==1		1			Y	1or2	
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 773 	            	1 	   	   	      	 	 	 