Step	Title                    	Time	Command     	Command     	Cmd         	Seq         	Telemetry   	Telemetry   	Expected    	Units 	Telemetry   	Other       	Crit        	Description              	Notes       	RT 	Tlm	Min	SIM   
\# 	                         	Req (m)	Description 	Mnemonic    	EGSE        	Key         	Description 	Mnemonic    	Value       	      	EGSE        	Verifier        	              	                         	            	Con	Fmt	Alt	Pos   
   	1.9\_V2.0                	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.0	Start DEA HK if necessary 	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.1	Load Board 11 DEA HK     	1   	loadDeaBlock	WD00001024  	            	            	 	            	            	      	Check cmdResult == OK 	            	       B 	Load Fullhouse DEA housekeeping	   	   	1or2   	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 225 	            	            	parameter block into slot 4	            	   	   	   	      
1.2	Start DEA Hkp run        	1   	startDEA    	XDZ0000005  	            	            	 	            	            	      	Check cmdResult == OK  	            	B            	get FP temp, should be stable 	 	  	  1or2 	   	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 18 	 		and $\pm2$~C of desired value    	 	  	  1or2 	   	      
2.0	Start heating FP to -90 C           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
2.1	verify power consumption  	10   	            	            	            	            	DEA Input I 	1DEICACU    	0.60--0.78           	A      	            	            	2            	DEA A Power should be $21\pm3$~W, 	            	Y  	1or2  	   	      
   	                         	    	            	            	            	            	DEA Input V 	1DE28AVO    	27.0-35.0           	V      	            	            	           	current is noisy so an avg. is needed 	            	Y  	1or2            	   	      
2.2	Set warm boot flag off   	1   	DPA Cold Boot	1WRMBTSB(0) 	            	            	            	            	            	      	            	            	            	disable Warm boot if BEP watchdogs	   	Y 	1or2 	   	      
2.3	Upload bakeout patch     	1   	writeBep    	WBBOEN\_ENB 	            	            	 	            	            	      	Check cmdResult == OK 	            	A 	Enable the "enable"      	            	Y  	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 101 	            	            	  	  	   	   	   	      
2.4	Enable the FP BO htr     	1   	changeConfigSetting	WSBAKENABL  	            	            	  	            	            	      	Check cmdResult == OK 	            	A          	enable the FP bakeout heater	If {\it psci} indicates a 	Y  	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 114 	            	            	  	{\scriptsize SWSTAT_DEAMAN_BADCNTLREG}	   	   	   	      
2.5	Set FP temp to -90~C     	1   	changeConfigSetting	WSFTNEG_90     	            	            		            	            	      	Check cmdResult == OK   	            	A         	Set desired FP temp to -90~C, 	or {\scriptsize SWSTAT_DEABOARD_ERROR,} 	Y  	1or2  	   	      
 	     	   	 	     	            	            		            	            	      	commandEcho 102   	            	        	FP bakeout htr comes on. 	bakeout enabled failed. 	 	 	   	      
2.6	dump system config.      	0.1   	dumpSysConfig	RS\_0000001 	            	            		            	            	      	Check cmdResult == OK  	            	      B     	get data to verify bakeout enable  	run {\it psci -a -l} to examine 	Y   	1or2  	     	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 66 	            	            	  	SysConfig packets. 	   	   	   	      
3.0	Verify FP stable at -90 C           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
3.1	wait for stabilization     	60   	            	            	            	            	FP Temp 	            	-90           	C      	deaHousekeepingData 	            	A            	verify FP temp stabilizes at -90~C  	Time depends on starting T 	P  	1or2  	   	      
   	                         	    	            	            	            	            	Cold Radiator T A 	 1CRAT           	 $\sim-110$  	C     	            	 	            	 	            	  	            	   	      
   	                         	    	            	            	            	            	Cold Radiator T B 	 1CRBT           	 $\sim-110$  	C     	            	 	            	 	            	  	            	   	      
 	 	  	   	    	            	            	Camera Body T A 	1CBAT    	-60          	C      	            	            	2            	should be at -60~C 	            	  	  	   	      
 	 	  	   	    	            	            	Camera Body T B 	1CBBT    	-60          	C      	            	            	2            	should be at -60~C 	            	  	  	   	      
 	 	  	   	    	            	            	Warm Radiator T A 	1WRAT    	-84          	C      	            	            	2            	 	            	  	  	   	      
 	 	  	   	    	            	            	Warm Radiator T B 	1WRBT    	-84          	C      	            	            	2            	 	            	  	  	   	      
																			
 	Total Time	76.1	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 