Step	Title                    	Time	Command     	Command     	Cmd         	Seq         	Telemetry   	Telemetry   	Expected    	Units 	Telemetry   	Other       	Crit        	Description              	Notes       	RT 	Tlm	Min	SIM   
#  	                         	Req (m)	Description 	Mnemonic    	EGSE        	Key         	Description 	Mnemonic    	Value       	      	EGSE        	Verifier    	            	                         	            	Con	Fmt	Alt	Pos   
   	2.5\_V2.0                	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1  	Turn off DPA B \& A        	    	            	            	            	            	            	            	            	      	            	            	            	 	            	   	   	   	      
1.1	DPA Power B off          	1   	DPA PS Off B	1DPPSBOF    	            	            	DPA PS B ON/OFF	1DPPSB      	OFF         	      	            	            	 2           	                         	            	Y   	1or2	   	      
   	                         	    	            	            	            	            	DPA B +5V Voltage	1DPP0BVO    	 $0.0\pm0.2$           	V     	            	            	            	                         	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input Current	1DPICBCU    	< 0.2       	A     	            	            	            	                         	            	   	   	   	      
1.2	Disable DPA Power B      	0.1 	DPA PS Disable B	1DPPSBDS    	            	            	DPA PS B ENB/DIS	1DPPSBX     	DIS         	      	            	            	 2           	                         	SF 4.9      	Y  	1or2	   	      
1.3	DPA Power A off          	1   	DPA PS Off A	1DPPSAOF    	            	            	 	     	         	      	            	            	            	                         	SF 4.9      	Y  	1or2	   	      
   	                         	    	            	            	            	            	DPA Input V A	1DPP0AVO    	$0.0\pm0.2$           	V     	            	            	            	                         	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input I A	1DPICACU    	< 0.2       	A     	            	            	            	                         	            	   	   	   	      
1.4	Disable DPA Power A      	0.1 	DPA PS Disable A	1DPPSADS    	            	            	 	            	            	      	            	            	            	power supply current <0.2 Amps	SF 4.9      	Y  	1or2	   	      
1.5	Enable DPA PS A          	0.1 	DPA PS A En 	1DPPSAEN    	            	            	            	            	            	      	            	            	            	No verifier before power is on	SF 4.4.1    	Y  	1or2	   	      
1.6	Turn on DPA PS A         	2   	DPA PS A On 	1DPPSAON    	            	            	DPA A ON/OFF	1DPPSA      	ON          	      	            	            	2            	                         	SF 4.4.1    	Y  	1or2	   	      
   	                         	    	            	            	            	            	DPA A ENB/DIS	1DPPSAX     	ENB         	      	            	            	            	                         	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input V A	1DP28AVO    	28.0--34.0          	V     	            	            	            	Expect about 12 Watts for side A,	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input I A	1DPICACU    	0.35--0.43        	A     	            	            	            	power consumption should be more	            	   	   	   	      
   	                         	    	            	            	            	            	DPA +5V     	1DPP0AVO    	4.9--5.5           	V     	            	            	            	stable than I or V.      	            	   	   	   	      
1.7 	Check BEP A Boot 	2.0 	            	            	            	            	            	            	            	     	Check bepStartupMessage:   	            	A   	   	   	 Y   	1or2 	 	 
   	                         	    	            	            	            	            	            	            	            	      	bepTickCounter $< 10$; version =11;	            	A  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	watchdogFlag = 0, patchValidFlag =1         	            	A   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	Check swHousekeeping messages:	            	   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	startingBepTickCounter $< 10$;            	            	B  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	endingBepTickCounter=  	            	B  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	=startingBepTickCounter+640  	            	  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	version =11 	            	A 	   	   	      	 	 	 
1.8 	Check HW LEDs    	2.0  	            	            	            	      	BEP Select 	1STAT4ST    	0          	     	            	            	2 	0 indicates BEP A is selected 	            	 Y 	1or2   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Full 	1STAT6ST    	1          	     	            	            	2 	1 means FIFO not full 	            	   	   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Empty 	1STAT7ST    	0         	     	            	            	2 	1 means FIFO not empty 	            	   	   	   	      
1.9 	Check SW LEDs    	2.0  	            	            	            	      	BEP initialization 	1STAT3ST    	0          	     	            	            	2 	0 means BEP SW is running 	            	 Y  	1or2   	   	      
   	   	    	            	            	            	      	Watchdog boot 	1STAT2ST    	1          	     	            	            	2 	1 means no watchdog boot 	            	   	   	   	      
   	   	    	            	            	            	      	Science run status	1STAT1ST    	1          	     	            	            	2 	1 means science idle 	            	   	   	   	      
   	   	    	            	            	            	      	  	1STAT0ST    	0or1          	     	            	            	2 	this bit toggles to indicate BEP is running	            	   	   	   	      
2  	Run BEP A/DEA A          	    	            	            	            	            	            	            	            	      	            	            	            	                         	LF 4.3.1    	   	   	   	      
2.1	Power up imaging boards  	1   	changeConfigSetting	WSI0I1I2    	            	            	 	            	            	      	Check cmdResult == 1  	            	 A           	Power I0,I1,I2 video boards.  	SF 4.4.3    	Y  	2  	   	      
 	   	   	 	    	  	  	 	 	  	  	commandEcho = 170   	            	            	 	    	  	  	   	      
   	                         	    	            	            	            	            	DEA Input V A	1DE28AVO    	28          	V     	            	            	            	Expect DEA side A power at about 	            	   	   	   	      
   	                         	    	            	            	            	            	DEA Input I A	1DEICACU    	1.13        	A     	            	            	            	31.5 Watts, current is noisy.	            	   	   	   	      
2.2	Power up Side-A FEPs     	1.5 	changeConfigSetting	WSFEP012    	            	            	 	            	            	      	 Check cmdResult == 1           	 	A         	turn on FEPs 0,1,2   	SF 4.4.4    	Y  	1or2  	   	      
 	   	   	 	    	  	  	 	 	  	  	commandEcho = 169   	            	            	 	    	  	  	   	      
   	                         	    	            	            	            	            	DPA Input V A	1DP28AVO    	28          	V     	            	            	            	Expect DPA Side A        	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input I A	1DPICACU    	1.4         	A     	            	            	            	power at about 38 Watts  	            	   	   	   	      
2.3	Load parameter block     	1   	loadTeBlock 	WT0001A014  	            	            	 	            	            	      	Check cmdResult == OK 	            	 A           	only clock I0,I1,I2. 	SF 4.5.1    	Y  	1or2  	   	      
 	   	   	 	    	  	  	 	 	  	  	commandEcho = 172   	            	            	 	    	  	  	   	      
2.4	Start science            	8   	startScience	XTZ0000005  	            	            	 	            	            	      	Check cmdResult == 1  		   A         	DEA Side A power to about 49 Watts	SF 4.5.1    	Y  	2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho = 58   	            	            	DPA Side A power to about 40 Watts	SF 4.5.1    	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	exposureTeFaintBias  	            	            	about 0 Watts on DPA side B,	            	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	Compare DEA tlm to Short Form	            	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	Appendix D               	            	   	   	   	      
2.5	Verify nominal operation 	5   	            	            	            	            	            	            	            	      	            	            	 B      	Run monitor\_noise on ACIS GSE	SF 4.5.2    	Y  	2  	   	      
2.6	Stop Science             	1   	stopScience 	AA00000000  	            	            	 	            	            	      	Check cmdResult == 1 		A            	scienceReport  	SF 4.5.3    	Y 	2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho = 1539            	            	            	Check terminationCode == 1	            	   	   	   	      
3  	Power-down               	    	            	            	            	            	            	            	            	      	            	            	            	                         	LF 4.7      	   	   	   	      
3.1	Power off video boards   	1   	changeConfigSetting	WSVIDALLDN  	            	            	 	            	            	      	 Check cmdResult == 1          	            	A        	   	SF 4.7      	Y  	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho = 1541    	            	            	DEA Side A power at about 21 Watts	            	   	   	   	      
3.2	Power off FEPs           	1   	changeConfigSetting	WSFEPALLDN  	            	            	 	            	            	      	Check cmdResult == 1  	            	 A           	    	SF 4.7      	Y  	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho = 1542    	            	            	 	            	   	   	   	      
3.3	DPA Power A off          	1   	DPA PS Off A	1DPPSAOF    	            	            	 	      	         	      	            	            	           	                         	SF 4.9      	Y  	1or2	   	      
   	                         	    	            	            	            	            	DPA Input V A	1DPP0AVO    	$0.0\pm0.2$           	V     	            	            	            	                         	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input I A	1DPICACU    	< 0.2       	A     	            	            	            	                         	            	   	   	   	      
3.4	Disable DPA Power A      	0.1 	DPA PS Disable A	1DPPSADS    	            	            	 	            	            	      	            	            	            	 	SF 4.9      	Y  	1or2	   	      
4  	Power DPA B/BEP B        	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
4.1	Enable DPA PS B          	0.1 	DPA PS B En 	1DPPSBEN    	            	            	            	            	            	      	            	            	            	No verifier before power is on	SF 4.4.1    	Y   	1or2	   	      
4.2	Turn on DPA PS B         	2   	DPA PS B On 	1DPPSBON    	            	            	DPA B ON/OFF	1DPPSB      	ON          	      	            	            	2            	                         	SF 4.4.1    	Y  	1or2	   	      
   	                         	    	            	            	            	            	DPA B ENB/DIS	1DPPSBX     	ENB         	      	            	            	            	                         	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input V B	1DP28BVO    	28.0--34.0          	V     	            	            	            	Expect about 9 Watts for side B,	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input I B	1DPICBCU    	0.26--0.32        	A     	            	            	            	power consumption should be more	            	   	   	   	      
   	                         	    	            	            	            	            	DPA +5V     	1DPP0BVO    	4.9--5.5           	V     	            	            	            	stable than I or V.      	            	   	   	   	      
4.3	Select BEP B             	1   	            	1BSELICL(1) 	            	            	            	            	            	      	            	            	            	1BSELICL=1 selects BEP B   	            	Y  	1or2	   	      
4.4	Set warm boot flag on     	1   	DPA Warm Boot	1WRMBTSB(1) 	            	            	            	            	            	      	            	            	            	Warm boot active BEP     	LF 4.4.1    	Y  	1or2 	   	      
4.5	Halt BEP                 	1   	DPA Command Reset	1RSETIRT(1) 	            	            	            	            	            	      	            	            	            	Hold active BEP reset line	LF 4.4.1    	Y  	1or2 	   	      
4.6	Restart BEP              	1   	            	1RSETIRT(0) 	            	            	            	            	            	      	bepStartupMessage 	 	A           	Release BEP reset line   	LF 4.4.1    	Y  	1or2	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	Check startup messages   	            	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	bepTickCounter $< 10$; version =11	            	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	watchdogFlag = 0, patchvalid Flag = 1        	            	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	warmbootFlag = 1  	            	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	Check swHousekeeping messages	            	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	startingBepTickCounter $< 10$;            	            	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	endingBepTickCounter =   	            	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	(startingBepTickCounter +640) 	            	   	   	   	      
4.7 	Check HW LEDs    	2.0  	            	            	            	      	BEP Select 	1STAT4ST    	1          	     	            	            	2 	1 indicates BEP B is selected 	            	 Y 	1or2   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Full 	1STAT6ST    	1          	     	            	            	2 	1 means FIFO not full 	            	   	   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Empty 	1STAT7ST    	0          	     	            	            	2 	1 means FIFO not empty 	            	   	   	   	      
4.8 	Check SW LEDs    	2.0  	            	            	            	      	BEP initialization 	1STAT3ST    	0          	     	            	            	2 	0 means BEP SW is running 	            	 Y  	1or2   	   	      
   	   	    	            	            	            	      	Watchdog boot 	1STAT2ST    	1          	     	            	            	2 	1 means no watchdog boot 	            	   	   	   	      
   	   	    	            	            	            	      	Science run status	1STAT1ST    	1          	     	            	            	2 	1 means science idle 	            	   	   	   	      
   	   	    	            	            	            	      	  	1STAT0ST    	0or1          	     	            	            	2 	this bit toggles to indicate BEP is running	            	   	   	   	      
5  	Run BEP B/DEA A          	    	            	            	            	            	            	            	            	      	            	            	            	                         	LF 4.3.1    	   	   	   	      
5.1	Power up I3,S2,S3 video   	1   	changeConfigSetting	WSI3S2S3    	            	            	 	            	            	      	Check cmdResult == 1 	     	 A   	Power I3,S2,S3 video boards. 	SF 4.4.3    	Y  	1or2  	   	      
   	boards                   	    	            	            	            	            	DEA Input V A	1DE28AVO    	28          	V     	commandEcho = 528  	            	            	Expect DEA side A power at about  	            	   	   	   	      
   	                         	    	            	            	            	            	DEA Input I A	1DEICACU    	1.13        	A     	            	            	            	 31.5 Watts, current is nosiy. 	            	   	   	   	      
5.2	Power up FEPs            	1.5 	changeConfigSetting	WSFEP345    	            	            	 	            	            	      	Check cmdResult == 1  	 	 A       	 Turn on FEPs 3,4,5. 	SF 4.4.4    	Y  	1or2  	   	      
   	                         	    	            	            	            	            	DPA Input V B	1DP28BVO    	28          	V     	commandEcho = 526 	            	            	Expect DPA Side B        	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input I B	1DPICBCU    	1.4         	A     	            	            	            	at about 38 Watts        	            	   	   	   	      
5.3	Load parameter block     	1   	loadTeBlock 	WT0001A014  	            	            	 	            	            	      	Check cmdResult == 1 	            	 A 	only clock I3,S2,S3.            	SF 4.5.1    	Y  	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho = 172  	            	            	   	            	   	   	   	      
5.4	Start science            	8   	startScience	XTZ0000005  	            	            	 	            	            	      	Check cmdResult == 1 		 A           	DEA Side A power to about 49 Watts	SF 4.5.1    	Y   	2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho = 58 	            	            	About 0 Watts on DPA Side A	SF 4.5.1    	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	exposureFaintBias  	            	            	About 40 Watts on DPA side B	SF 4.5.1    	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	Compare DEA telemetry to SF App. D.	            	   	   	   	      
5.5	Verify nominal operation 	5   	            	            	            	            	            	            	            	      	            	            	A    	Run monitor\_noise on ACIS GSE	SF 4.5.2    	Y  	2  	   	      
5.6	Stop Science             	1   	stopScience 	AA00000000  	            	            	 	            	            	      	Check cmdResult == 1 		 A  	scienceReport    	SF 4.5.3    	Y   	2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho = 1539 	            	            	 	            	   	   	   	      
6  	Power-down               	    	            	            	            	            	            	            	            	      	            	            	            	                         	LF 4.7      	   	   	   	      
6.1	Power off video boards   	1   	changeConfigSetting	WSVIDALLDN  	            	            	 	            	            	      	Check cmdResult == 1  	            	A       	    	SF 4.7      	Y  	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho = 1541 	            	            	 	            	   	   	   	      
6.2	Power off FEPs           	1   	changeConfigSetting	WSFEPALLDN  	            	            	 	            	            	      	Check cmdResult == 1   	            	A      	    	SF 4.7      	Y  	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho = 1542 	            	            	 	            	   	   	   	      
7  	Switch back to BEP-A	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
7.1	Halt BEP                 	1   	DPA Command Reset	1RSETIRT(1) 	            	            	            	            	            	      	            	            	            	Hold active BEP reset line	LF 4.4.1    	Y  	1or2 	   	      
																			
7.2	Select BEP A            	1   	            	1BSELICL(0) 	            	            	            	            	            	      	            	            	            	1BSELICL=0 selects BEP A   	            	Y   	1or2	   	      
7.3	Enable DPA PS A          	0.1   	DPA PS A En 	1DPPSAEN    	            	            	DPA A ENB/DIS            	1DPPSAX           	 ENB           	      	            	            	2           	 	SF 4.4.1    	Y   	1or2  	   	      
7.4	Turn on DPA PS A         	1   	DPA PS A On 	1DPPSAON    	            	            	DPA A ON/OFF	1DPPSA      	ON           	      	            	            	2         	                         	SF 4.4.1    	Y  	1or2         	   	      
   	                         	    	            	            	            	            	DPA A ENB/DIS	1DPPSAX     	ENB           	      	            	            	1            	                         	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input V A 	1DP28AVO    	28.0--34.0           	V      	            	            	2              	Expect 12~W for side A, power  	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input I A 	1DPICACU    	0.35--0.43           	A      	            	            	2            	consumption should be more 	            	   	   	   	      
   	                         	    	            	            	            	            	DPA +5V     	1DPP0AVO    	4.9--5.5           	V      	            	            	2            	stable than I or V.      	            	   	   	   	      
7.5 	Check BEP A Boot 	2.0 	            	            	            	            	            	            	            	     	Check bepStartupMessage:   	            	A   	   	   	 Y   	1or2 	 	 
   	                         	    	            	            	            	            	            	            	            	      	bepTickCounter $< 10$; version =11;	            	A  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	watchdogFlag = 0, patchValidFlag =1         	            	A   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	warmbootFlag = 0   	            	A   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	Check swHousekeeping messages:	            	   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	startingBepTickCounter $< 10$;            	            	B  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	endingBepTickCounter=  	            	B  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	=startingBepTickCounter+640  	            	  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	version =11 	            	A 	   	   	      	 	 	 
7.6 	Check HW LEDs    	2.0  	            	            	            	      	BEP Select 	1STAT4ST    	0          	     	            	            	2 	0 indicates BEP A is selected 	            	 Y 	1or2   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Full 	1STAT6ST    	1          	     	            	            	2 	1 means FIFO not full 	            	   	   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Empty 	1STAT7ST    	0          	     	            	            	2 	1 means FIFO not empty 	            	   	   	   	      
7.7 	Check SW LEDs    	2.0  	            	            	            	      	BEP initialization 	1STAT3ST    	0          	     	            	            	2 	0 means BEP SW is running 	            	 Y  	1or2   	   	      
   	   	    	            	            	            	      	Watchdog boot 	1STAT2ST    	1          	     	            	            	2 	1 means no watchdog boot 	            	   	   	   	      
   	   	    	            	            	            	      	Science run status	1STAT1ST    	1          	     	            	            	2 	1 means science idle 	            	   	   	   	      
   	   	    	            	            	            	      	  	1STAT0ST    	0or1          	     	            	            	2 	this bit toggles to indicate BEP is running	            	   	   	   	      
 	Total Time	69.6	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 