Step	Title                    	Time	Command     	Command     	Cmd         	Seq         	Telemetry   	Telemetry   	Expected    	Units 	Telemetry   	Other       	Crit        	Description              	Notes       	RT 	Tlm	Min	SIM   
\# 	                         	Req (m)	Description 	Mnemonic    	EGSE        	Key         	Description 	Mnemonic    	Value       	      	EGSE        	Verifier        	              	                         	            	Con	Fmt	Alt	Pos   
   	1.7\_V2.0               	    	            	            	            	            	            	            	            	                                           	            	            	            	                         	            	   	   	   	      
1.0	Measure Pressure         	    	            	            	            	            	            	            	            	                                           	            	            	            	                         	            	   	   	   	      
1.1	turn on Pressure Transducer A  	1   	XDCR A on   	1PRESAON    	            	            	Pressure XDCR A    	1PRDBAON    	ENB          	      	            	            	2            	                         	            	Y  	1or2            	   	      
1.2	turn on Pressure Transducer B  	1   	XDCR B on   	1PRESBON    	            	            	Pressure XDCR B   	1PRDBBON    	ENB           	      	            	            	2            	                         	            	Y  	1or2            	   	      
1.3	Measure Pressure A       	2   	            	            	            	            	Differential Housing  	1HOPRAPR    	$0\pm2$           	T     	            	            	2           	                         	            	Y  	1or2         	   	      
   	                         	    	            	            	            	            	Pressure A  	            	            	      	            	            	            	                         	            	   	         	   	      
1.4	Measure Pressure B       	    	            	            	            	            	Differential Housing  	1HOPRBPR    	$0\pm2$           	T     	            	            	2           	                         	            	Y  	1or2         	   	      
   	                         	    	            	            	            	            	Pressure B  	            	            	      	            	            	            	                         	            	   	         	   	      
2.0	Measure FP temperature           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
2.1	Load Board 11 DEA HK     	1   	loadDeaBlock	WD00001024  	            	            	 	            	            	      	Check cmdResult == OK 	            	       B 	Load Fullhouse DEA housekeeping	   	   	1or2   	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 225 	            	            	parameter block into slot 4	            	   	   	   	      
2.2	Start DEA Hkp run        	1   	startDEA    	XDZ0000005  	  	 	 	            	            	      	Check cmdResult == OK 	 	B            	get FP temp from deaHousekeepingData   	 	  	  1or2 	   	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 18 	 		    	 	  	 	   	      
2.3	Record FP temp           	2   	            	            	            	            	   	            	$<-50$           	C      	deaHousekeepingData 	            	B            	                         		Y  	1or2  	   	      
3  	Dump Config Info         	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
3.1	dump default TE PBs      	0.1   	dumpParameterSlots	RT\_0000001 	            	            	 	            	            	      	Check cmdResult == OK 	            	 B         	                         	{\it psci} should not indicate 	Y 	2  	60k  	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 78 	 		  	any errors regarding 	  	 	   	      
3.2	dump default CC PBs      	0.1   	dumpParameterSlots	RC\_0000001 	            	            		            	            	      	Check cmdResult == OK 	            	  B         	                         	``truncated blocks'' for  	Y  	2  	  60k   	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 75 	 		  	any of these dumps.  	  	 	   	      
3.3	dump default 2D PBs      	0.1   	dumpParameterSlots	R2\_0000001 	            	            		            	            	      	Check cmdResult == OK 	            	  B         	                         	 	Y  	2  	60k     	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 72 	 		  	 	  	 	   	      
3.4	dump default 1D PBs      	0.1   	dumpParameterSlots	R1\_0000001 	            	            		            	            	      	Check cmdResult == OK	            	   B        	                         		Y  	2  	60k  	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 71 	 		  	 	  	 	   	      
3.5	dump default DeaHk PBs   	0.1   	dumpParameterSlots	RD\_0000001 	            	            		            	            	      	Check cmdResult == OK	            	   B        	                         	            	Y  	2  	     	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 63 	 		  	 	  	 	   	      
3.6	dump system config.      	0.1   	dumpSysConfig	RS\_0000001 	            	            		            	            	      	Check cmdResult == OK  	            	      B     	verify video boards \& FEPs off  	            	Y   	2  	     	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 66 	 		  	 	  	 	   	      
3.7	dump bad pixel list      	0.5   	dumpBadPixels	RP\_0000001 	            	            		            	            	      	Check cmdResult == OK         	         	  B	                       	            	Y 	2  	     	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 83 	 		  	 	  	 	   	      
3.8	dump bad TE columns      	0.1   	dumpBadTeColumn	R4\_0000001 	            	            		            	            	      	Check cmdResult == OK  	          	  B	                  	            	Y  	2  	     	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 80 	 		  	 	  	 	   	      
3.9	dump bad CC columns      	0.1   	dumpBadCcColumn	R3\_0000001 	            	            		            	            	      	Check cmdResult == OK 	            	B	                       	            	Y 	2  	     	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 77 	 		  	 	  	 	   	      
3.10	dump Huffman tables      	0.5   	dumpHuffman 	RH\_0000001 	            	            		            	            	      	Check cmdResult == OK 	            	   B	                   	            	Y 	2  	     	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 68 	 		  	 	  	 	   	      
3.11	dump patches             	2   	dumpPatchlist	RU\_0000001 	            	            		            	            	      	Check cmdResult == OK 	            	B 	                   	            	Y 	2  	     	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 65 	 		  	 	  	 	   	      
4.0	Heat FP to -50~C         	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
4.1	verify power consumption  	10   	            	            	            	            	DEA Input I 	1DEICACU    	0.60--0.78           	A      	            	            	2            	DEA A Power should be $21\pm3$~W, 	            	Y  	1or2  	   	      
   	                         	    	            	            	            	            	DEA Input V 	1DE28AVO    	27.0-35.0           	V      	            	            	           	current is noisy so an avg. is needed 	            	Y  	1or2            	   	      
4.2	Set warm boot flag off   	1   	DPA Cold Boot	1WRMBTSB(0) 	            	            	            	            	            	      	            	            	            	disable Warm boot if BEP watchdogs	   	Y 	1or2 	   	      
4.3	Upload bakeout patch     	1   	writeBep    	WBBOEN\_ENB 	            	            	 	            	            	      	Check cmdResult == OK 	            	A 	Enable the "enable"      	            	Y  	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 101 	            	            	  	  	   	   	   	      
4.4	Enable the FP BO htr     	1   	changeConfigSetting	WSBAKENABL  	            	            	  	            	            	      	Check cmdResult == OK 	            	A          	enable the FP bakeout heater	If {\it psci} indicates a 	Y  	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 114 	            	            	  	{\scriptsize SWSTAT_DEAMAN_BADCNTLREG}	   	   	   	      
4.5	Set FP temp to -50~C     	1   	changeConfigSetting	WSFTNEG_50     	            	            		            	            	      	Check cmdResult == OK   	            	A         	Set desired FP temp to -50~C, 	or {\scriptsize SWSTAT_DEABOARD_ERROR,} 	Y  	1or2  	   	      
 	     	   	 	     	            	            		            	            	      	commandEcho 163   	            	        	FP bakeout htr comes on. 	bakeout enabled failed. 	 	 	   	      
4.6	dump system config.      	0.1   	dumpSysConfig	RS\_0000001 	            	            		            	            	      	Check cmdResult == OK  	            	      B     	get data to verify bakeout enable  	run {\it psci -a -l} to examine 	Y   	1or2  	     	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 66  	            	            	  	SysConfig packets. 	   	   	   	      
4.7	monitor FP temp          	40   	            	            	            	            	 	            	-50           	C      	deaHousekeepingData 	            	A            	                         	Time depends on starting T 	P  	1or2  	   	      
5.0	Enable Large Valve              	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
5.1	Enable vent valve B      	1   	V V Enable B	1VVCBEN     	            	            	VV Open Drive B   	1VVDBBON    	ENB          	      	            	            	1           	                         	            	Y   	1or2  	   	      
5.2	Verify Actuator temps    	2   	            	            	            	            	VV Open Act. B T	1VAHOBT     	$<+30$          	C      	            	            	2          	                         	            	Y  	1or2  	   	      
   	                         	    	            	            	            	            	VV Close Act. B T	1VAHCBT     	$<+30$           	C      	            	            	2           	                         	            	Y  	1or2           	   	      
5.3	Verify close bit          	2    	            	            	            	            	            	1VVCLBCL    	CLOS           	      	            	            	1            	0 means valve is closed  	            	Y   	1or2  	   	      
5.4	Verify open bit          	2    	            	            	            	            	            	1VVOPBOP    	NOPE          	      	            	            	1            	1 means valve is not fully open                       	            	Y   	1or2  	   	      
6.0	Open Large Valve              	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
6.1	Open valve B             	1   	V V Open On B	1VVCOBON    	            	            	Vent Valve Open B	1VVODBOP    	ON         	      	            	            	1           	1 means actuator is on  	            	Y  	1or2  	   	      
7.0	Monitor Actuator Motion    	    	            	            	            	            	            	            	            	      	            	                     	            	                         	            	   	   	   	      
7.1	Monitor actuator temp          	20   	            	            	            	            	            	1VAHOBT     	120         	C      	            	            	1            	declare contingency \& execute  	            	Y   	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	abort if temp exceeds 120~C 	            	   	   	   	      
7.2	Verify close bit          	    	            	            	            	            	            	1VVCLBCL    	NCLO       	      	            	            	1            	$0\Rightarrow1$ indicates mechanism  	            	Y   	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	is opening                         	            	   	          	   	      
7.3	Verify open bit          	    	            	            	            	            	            	1VVOPBOP    	OPEN          	      	            	            	1            	$1\Rightarrow0$ indicates mechanism                         	            	Y   	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	has opened                         	            	   	         	   	      
8.0	Turn Off Valve B           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
8.1	Turn off valve B          	2   	V V Open Off B   	1VVCOBOF    	            	            	 Vent Valve Open B   	1VVODBOP    	OFF           	      	            	            	1            	0 means actuator is off 	            	Y  	1or2  	   	      
9.0	Monitor Actuator cooldown 	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
9.1	Monitor actuator temps   	30   	            	            	            	            	VV Open Act. B T 	1VAHOBT     	+50    	C      	            	            	1            	temp goes from +120 to +50~C 	should take 30 minutes to drop  	Y   	1or2  	   	      
   	                         	    	            	            	            	            	VV Close Act. B T	1VAHCBT     	$<+30$           	C      	            	            	1           	                         	            	  	           	   	      
10.0	Disable Valve B           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
10.1	Disable valve B          	2   	VV Disable B   	1VVCBDS     	            	            	VV Open Drive B   	1VVDBBON    	DIS          	      	            	            	2            	                         	            	Y  	1or2  	   	      
11.0	Maintain FP temp of -50~C 	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
11.1	monitor Camera body temp  	2   	            	            	            	            	Camera Body T A 	1CBAT     	-60           	C      	            	            	2            	 	            	P  	1or2  	   	      
  	   	   	            	            	            	            	Camera Body T B 	1CBBT     	-60           	C      	            	            	2            	 	            	  	  	   	      
11.2	monitor FP temp           	180    	            	            	            	            	 	            	-50           	C      	deaHousekeepingData 	            	A           	leave FP at -50~C 	 	P  	1or2  	   	      
12.0	Turn Off XDCRs 	    	            	            	            	            	            	            	            	                                           	            	            	            	                         	            	   	   	   	      
12.1	turn off Pressure Transducer A  	0.1   	XDCR A on   	1PRESAOF    	            	            	Pressure XDCR A    	1PRDBAON    	OFF          	      	            	            	2            	                         	verifiers only valid if one 	 	1,2 or 4            	   	      
12.2	turn off Pressure Transducer B  	0.1   	XDCR B on   	1PRESBOF    	            	            	Pressure XDCR B   	1PRDBBON    	OFF           	      	            	            	2            	                         	side of the DPA is on	   	1,2 or 4            	   	      
12.3	Measure Pressure A       	2.0    	            	            	            	            	Differential Housing  	1HOPRAPR    	-21.1    	T     	            	            	1            	                         	            	   	1or2          	   	      
   	                         	    	            	            	            	            	 Pressure A  	            	            	      	            	            	            	                         	            	   	         	   	      
12.4	Measure Pressure B       	  	            	            	            	            	Differential Housing  	1HOPRBPR    	-19.1        	T     	            	            	1           	                         	            	   	1or2         	   	      
   	                         	    	            	            	            	            	Pressure B  	            	            	      	            	            	            	                         	            	   	         	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
 	Total Time	312.1	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 