Step	Title                    	Time	Command     	Command     	Cmd         	Seq         	Telemetry   	Telemetry   	Expected    	Units 	Telemetry   	Other       	Crit        	Description              	Notes       	RT 	Tlm	Min	SIM   
\# 	                         	Req (m)	Description 	Mnemonic    	EGSE        	Key         	Description 	Mnemonic    	Value       	      	EGSE        	Verifier        	              	                         	            	Con	Fmt	Alt	Pos   
   	5.13\_V1.0                	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.0	Verify Initial Temperatures   	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.1 	Verify SIM position 	 1 	   	    	            	            	SIM TT Position 	3TSCPOS   	75624          	      	            	            	1            	should be at ACIS-S 	            	Y  	1or2  	   	      
1.2 	Verify HW Temperatures 	  	   	    	            	            	Camera Body T A 	1CBAT    	$+22.8\pm2$          	C      	            	            	2            	should be at $+22.8\pm2$~C 	            	Y  	1or2  	   	      
 	 	  	   	    	            	            	Camera Body T B 	1CBBT    	$+17.8\pm2$    	C      	            	            	2            	should be at $+17.8\pm2$~C 	            	  	  	   	      
  	                         	    	            	            	            	            	Cold Radiator T A 	 1CRAT           	 $\sim-50.0$  	C     	            	 	            	 	            	  	            	   	      
   	                         	    	            	            	            	            	Cold Radiator T B 	 1CRBT           	 $\sim-47.5$  	C     	            	 	            	 	            	  	            	   	      
 	 	  	   	    	            	            	Warm Radiator T A 	1WRAT    	$\sim-37.6$          	C      	            	            	2            	 	            	  	  	   	      
 	 	  	   	    	            	            	Warm Radiator T B 	1WRBT    	$\sim-37.6$          	C      	            	            	2            	 	            	  	  	   	      
1.2	verify FP temperature    	2   	            	            	            	            	FP Temp 	            	$\sim -60.0$           	C      	deaHousekeepingData 	            	A            	verify FP temp stable at desired temp. 	 	Y  	1or2  	   	      
2.0	Start Cooling DH to -60 C           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
2.1	Housing Bakeout Off B    	1   	Housing B.O. Off B	1HBOBOF     	            	            	DA BO B On/Off 	1DABOBON    	OFF            	      	            	            	            	                         	            	Y   	1or2  	   	      
   	                         	    	            	            	            	            	DA Htr Output V B 	1DAHBVO 	0.0           	 V     	            	            	1           	voltage should drop to 0  	            	 	            	   	      
   	                         	    	            	            	            	            	DA Htr Current B  	1DAHBCU  	0.0         	A      	            	    	1           	current should drop to zero  	            	  	            	   	      
2.2 	Housing Bakeout Dis B    	1   	Housing B.O. Dis B	1HBOBDS     	            	            	DA BO B Enb/Dis 	1DABOBEN    	DIS            	      	            	            	            	                         	            	Y  	1or2   	   	      
2.3	monitor Camera Body temp  	720   	            	            	            	            	Camera Body T A 	1CBAT     	$<+22.8$           	C      	            	            	2            	wait for a significant 	            	P  	1or2  	   	      
 	 	  	   	    	            	            	Camera Body T B 	1CBBT    	$<+17.8$    	C      	            	            	2            	drop below $+22.8/17.8\pm2$~C 	            	  	  	   	      
3.0	Disable FP bakeout       	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
3.1 	Verify Camera Body Temp 	10  	   	    	            	            	Camera Body T A 	1CBAT    	$\le-55.0$          	C      	            	            	2            	should be at $\le-55.0$~C 	            	Y  	1or2  	   	      
 	 	  	   	    	            	            	Camera Body T B 	1CBBT    	$\le-55.0$    	C      	            	            	2            	 	            	  	  	   	      
3.2	set FP temp to -121~C    	2   	ChangeConfigSetting 	WSFTNEG121     	            	            	 	            	            	      	Check cmdResult == 1 	            	A            	 	            	Y  	1or2  	   	      
  	    	    	 	     	            	            	 	            	            	      	commandEcho 1220  	            	            	 	            	  	  	   	      
3.3	turn off FP bakeout htr 	2   	ChangeConfigSetting 	WSBAKDSABL  	            	            	 	            	            	      	 Check cmdResult == 1 	            	A            	          	            	Y  	1or2  		      
  	     	   	 	  	            	            	 	            	            	      	commandEcho 116            	            	           	          	            	Y  	1or2  		      
3.4	disable bakeout patch    	2   	writeBep    	WBBOEN\_DIS 	            	            	 	            	            	      	 Check cmdResult == 1     	            	   A         	          	            	Y 	1or2   	   	      
  	     	   	 	  	            	            	 	            	            	      	commandEcho 99            	            	           	          	            	  	  		      
3.5	set warm boot flag on    	0.1   	DPA Warm Boot	1WRMBTSB(1) 	            	            	            	        	            	      	            	            	2            	                         	            	Y  	1or2  		      
3.6	Halt BEP                 	0.1   	DPA Command Reset	1RSETIRT(1) 	            	            	            	       	            	      	            	            	2            	1RSETIRT=1 holds board in reset	         	Y  	1or2  		      
3.7	Restart BEP              	0.1   	DPA Command Reset	1RSETIRT(0) 	            	            	 	            	            	      	            	            	2           	1RSETIRT=0 releases board 	         	Y  	1or2  		      
3.8 	Check BEP A Boot 	2.0 	            	            	            	            	            	            	            	     	Check bepStartupMessage:   	            	A   	   	   	 Y   	1or2 	 	 
   	                         	    	            	            	            	            	            	            	            	      	bepTickCounter $< 10$; warmbootFlag =1;	            	A  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	watchdogFlag = 0, patchValidFlag =1         	            	A   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	Check swHousekeeping messages:	            	   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	startingBepTickCounter $< 10$;            	            	B  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	endingBepTickCounter=  	            	B  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	=startingBepTickCounter+640;  	            	  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	ACIS EGSE verifies ``version''  	            	  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	field == 30 decimal  	            	  	   	   	      	 	 	 
3.9 	Check HW LEDs    	2.0  	            	            	            	      	BEP Select 	1STAT4ST    	0          	     	            	            	2 	0 indicates BEP A is selected 	            	 Y 	1or2   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Full 	1STAT6ST    	1          	     	            	            	2 	1 means FIFO not full 	            	   	   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Empty 	1STAT7ST    	0         	     	            	            	2 	1 means FIFO not empty 	            	   	   	   	      
3.10	 Check SW LEDs    	2.0  	            	            	            	      	BEP initialization 	1STAT3ST    	0          	     	            	            	2 	0 means BEP SW is running 	            	 Y  	1or2   	   	      
   	   	    	            	            	            	      	Watchdog boot 	1STAT2ST    	1          	     	            	            	2 	1 means no watchdog boot 	            	   	   	   	      
   	   	    	            	            	            	      	Science run status	1STAT1ST    	1          	     	            	            	2 	1 means science idle 	            	   	   	   	      
   	   	    	            	            	            	      	  	1STAT0ST    	0or1          	     	            	            	2 	this bit toggles to indicate BEP is running	            	   	   	   	      
4.0	Monitor FP Temp           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
4.1	Load Board 11 DEA HK     	1   	loadDeaBlock	WD00001024  	            	            	 	            	            	      	Check cmdResult == OK 	            	       B 	Load Fullhouse DEA housekeeping	   	Y 	1or2   	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 225  	    	            	parameter block into slot 4	            	   	   	   	      
4.2	Start DEA Hkp run        	1   	startDEA    	XDZ0000005  	            	            	 	            	            	      	Check cmdResult == OK 	            	B            	get FP temp from DEA HKP data   	 	Y 	  1or2 	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 18  	    	            	 	            	   	   	   	      
4.3	dump system config.      	0.1   	dumpSysConfig	RS\_0000001 	            	            		            	            	      	Check cmdResult == OK  	            	      B     	  	            	Y   	1or2  	     	      
   	                         	    	            	            	            	            	            	            	            	      	 commandEcho 66 	   	            	 	            	   	   	   	      
4.4	Monitor FP temp    	30   	 	     	  	          	FP Temp 	            	 $<-60$            	C      	deaHousekeepingData  	            	A    	after $\sim1/2$~hr, should be convinced temp is  	 	Y  	1or2  	   	      
  	    	    	 	     	  	          	 	            	           	      	  	            	    	dropping, objective is stabilization at -120~C 	 	P  	1or2  	   	      
5.0	Translate SIM to HRC-S           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
5.1 	FOT translates SIM to HRC-S 	 5 	   	    	            	            	  	   	          	      	            	            	1            	 	            	Y 	1or2  	   	      
5.2 	Verify SIM position 	 1 	   	    	            	            	SIM TT Position 	3TSCPOS   	-99616         	      	            	            	1            	should be at HRC-S 	            	Y  	1or2  	   	      
 	Total Time	785.4	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 