Step	Title                    	Time	Command     	Command     	Cmd         	Seq         	Telemetry   	Telemetry   	Expected    	Units 	Telemetry   	Other       	Crit        	Description              	Notes       	RT 	Tlm	Min	SIM   
\# 	                         	Req (s)	Description 	Mnemonic    	EGSE        	Key         	Description 	Mnemonic    	Value       	      	EGSE        	Verifier        	              	                         	            	Con	Fmt	Alt	Pos   
   	4.2\_V2.0                	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.0	Turn on DEA A            	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.1	Enable DEA PS A          	1.0   	DEA PS A En 	1DEPSAEN    	            	            	     	      	            	      	            	            	            	Use currents \& 	    	   	1or2  	   	      
1.2	DEA Power A On           	10.0   	DEA PS On A 	1DEPSAON    	            	            	            	 	            	      	            	  	            	  	  	   	1or2   	   	      
2.0	Turn on DPA A          	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
2.1	Enable DPA PS A          	1.0   	DPA PS A En 	1DPPSAEN    	            	            	            	            	            	      	            	            	            	No verifier before       	            	   	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	power is on              	            	   	   	   	      
2.2	Turn on DPA PS A         	10.0   	DPA PS A On 	1DPPSAON    	            	            	DPA A ON/OFF	1DPPSA      	ON           	      	            	            	2           	                         	            	   	1or2            	   	      
3.0	Turn on DPA B           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
3.1	Enable DPA PS B          	1.0   	DPA PS B En 	1DPPSBEN    	            	            	 DPA B Enb 	1DPPSBX           	ENB            	      	            	            	 2           	     	            	  	1or2  	   	      
3.2	Turn on DPA PS B         	1.0 	DPA PS B On 	1DPPSBON    	            	            	DPA B on    	1DPPSB      	ON           	      	            	            	2     	                         	            	  	1or2            	   	      
4.0	Verify proper state           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
4.1	Verify DPA  A is on        	   	  	    	            	            	DPA A ON/OFF	1DPPSA      	ON           	      	            	            	2           	                         	            	   	1or2            	   	      
   	                         	    	            	            	            	            	DPA A ENB/DIS	1DPPSAX     	ENB           	      	            	            	2            	                         	            	   	   	   	      
   	                         	    	            	            	            	            	DPA +5V     	1DPP0AVO    	4.9--5.5    	V      	            	            	1            	      	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input V 	1DP28AVO    	28.0--34.0    	V      	            	            	2            	Expect 12~W for side A, power consumption 	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input I 	1DPICACU    	0.35--0.43       	A      	            	            	2            	should be more stable than I or V. 	            	   	   	   	      
4.2	Verify DPA B is on        	  	 	    	            	            	DPA B on    	1DPPSB      	ON           	      	            	            	2     	                         	            	  	1or2            	   	      
   	                         	    	            	            	            	            	DPA B ENB/DIS	1DPPSBX     	ENB           	      	            	            	2            	                         	            	   	   	   	      
   	                         	    	            	            	            	            	DPA +5V     	1DPP0BVO    	4.9--5.5           	V      	            	            	1            	     	            	   	   	   	      
 	                     	    	            	            	            	            	DPA Input V 	1DP28BVO    	28.0--34.0       	V      	            	            	2            	Expect 9~W for side B, power consumption  	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input I 	1DPICBCU    	0.26--0.32           	A      	            	            	2            	should be more stable than I or V.  	            	   	   	   	      
4.3 	Verify DEA A is On    	    	            	            	            	      	DEA A ENB/DIS	1DEPSAX    	ENB          	     	            	            	2  	                         	            	   	1or2   	   	      
   	                         	    	            	            	            	      	DEA A ENB/DIS	1DEPSA    	ON          	     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	       	DEA Input V A	1DE28AVO    	28.0--34.0          	V     	            	            	2 	Expect DEA side A ower $21\pm3$~W,      	            	   	   	   	      
   	                         	    	            	            		      	DEA Input I A	1DEICACU    	0.62--0.75        	A     	 	 	2	current is noisy so an average is needed. 	            	   	   	   	      
   	                         	    	            	            	            	      	DEA +24 V A 	1DEP2AVO    	24.0--26.0          	V     	            	            	1 	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA +6 V A  	1DEP0AVO    	5.6--6.7           	V     	            	            	2 	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA -6 V A  	1DEN0AVO    	-7.0-- -5.7          	V     	            	            	2 	                         	            	   	   	   	      
   	                         	    	            	            	            	       	DEA +15 V A 	1DEP1AVO    	15.0--17.0          	V     	            	            	2 	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA -15 V A 	1DEN1AVO     	-17.0-- -15.0         	V     	            	            	2 	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA +28 V A 	1DEP3AVO    	>26.0          	V     	            	            	2 	                         	            	   	   	   	      
4.4   	Verify DEA B is off                         	    	            	            	            	      	DEA Input I B	1DEICBCU    	<0.2        	A     	            	            	 	  	            	   	1or2   	   	      
   	                         	    	            	            	            	      	DEA +6 V B  	1DEP0BVO    	$0.0\pm0.2$     	V     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA -6 V B  	1DEN0BVO    	$0.0\pm0.2$        	V     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	       	DEA +15 V B 	1DEP1BVO    	$0.0\pm0.2$      	V     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA -15 V B 	1DEN1BVO     	$0.0\pm0.2$   	V     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA +24 V B 	1DEP2BVO    	$0.0\pm0.2$       	V     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA +28 V B 	1DEP3BVO    	$0.0\pm0.2$        	V     	            	            	   	                         	            	   	   	   	      
4.5 	Check BEP A Boot 	    	            	            	            	            	            	            	            	     	Check bepStartupMessage:   	            	A   	   	   	   	1or2 	 	 
    	                         	    	            	            	            	            	            	            	            	      	bepTickCounter $< 10$; version =11;	            	A  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	watchdogFlag = 0, patchValidFlag =1         	            	A   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	warmbootFlag = 0   	            	A   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	Check swHousekeeping messages:	            	   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	startingBepTickCounter $< 10$;            	            	B  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	endingBepTickCounter=  	            	B  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	=startingBepTickCounter+640  	            	  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	version =11 	            	A 	   	   	      	 	 	 
4.6 	Check HW LEDs    	     	            	            	            	      	BEP Select 	1STAT4ST    	0          	     	            	            	2 	0 indicates BEP A is selected 	            	  	1or2   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Full 	1STAT6ST    	1          	     	            	            	2 	1 means FIFO not full 	            	   	   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Empty 	1STAT7ST    	0          	     	            	            	2 	1 means FIFO not empty 	            	   	   	   	      
4.7 	Check SW LEDs    	     	            	            	            	      	BEP initialization 	1STAT3ST    	0          	     	            	            	1 	0 means BEP SW is running 	            	  	1or2   	   	      
   	   	    	            	            	            	      	Watchdog boot 	1STAT2ST    	1          	     	            	            	2 	1 means no watchdog boot 	            	   	   	   	      
   	   	    	            	            	            	      	Science run status	1STAT1ST    	1          	     	            	            	2 	1 means science idle 	            	   	   	   	      
   	   	    	            	            	            	      	  	1STAT0ST    	0or1          	     	            	            	2 	this bit toggles to indicate BEP is running	            	   	   	   	      
																			
 	Total Time	24	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 