Step	Title                    	Time	Command     	Command     	Cmd         	Seq         	Telemetry   	Telemetry   	Expected    	Units 	Telemetry   	Other       	Crit        	Description              	Notes       	RT 	Tlm	Min	SIM   
\# 	                         	Req (m)	Description 	Mnemonic    	EGSE        	Key         	Description 	Mnemonic    	Value       	      	EGSE        	Verifier        	              	                         	            	Con	Fmt	Alt	Pos   
   	5.7\_V2.0                	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.0	Turn off DA Housing htr A 	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.1	turn off housing heater A  	1   	Housing Htr Off A  	1HHTRAOF    	            	            	DA A ON/OFF 	1DAHTAON    	OFF           	      	            	            	2            	Verifier only valid of one side of the DPA is on. 	            	Y  	1,2,4or6  	   	      
   	    	    	            	            	            	            	DA Htr +28V INPUT A 	1DAHHAVO 	 $0.0\pm0.2$          	V   	            	            	             	  	            	  	   	   	      
   	                         	    	            	            	            	            	DA Htr Output V A 	1DAHAVO 	  $0.0\pm0.2$        	 V     	            	            	             	  	            	 	            	   	      
   	                         	    	            	            	            	            	DA Htr Current A  	1DAHACU  	<0.2         	A      	            	    	           	   	            	  	            	   	      
1.2	disable housing heater A  	1   	Housing Htr Dis A  	1HHTRADS    	            	            	DA A ENB/DIS 	1DAHTAEN    	DIS           	      	            	            	2            	Verifier only valid of one side of the DPA is on. 	            	Y  	1,2,4or6  	   	      
2.0	Turn on DA Housing htr B 	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
2.1	enable housing heater B  	1   	Housing Htr En B   	1HHTRBEN    	            	            	DA B ENB/DIS 	1DAHTBEN    	ENB           	      	            	            	2            	Verifier only valid of one side of the DPA is on. 	            	Y  	1,2,4or6  	   	      
2.2	turn on housing heater B  	1   	Housing Htr On B   	1HHTRBON    	            	            	DA B ON/OFF 	1DAHTBON    	ON           	      	            	            	2            	Verifier only valid of one side of the DPA is on. 	            	Y  	1,2,4or6  	   	      
  	  	    	            	            	            	            	DA Htr +28V INPUT B 	1DAHHBVO 	 28.0--32.0          	V   	            	            	             	values shown are maximum voltage and current	            	  	            	   	      
   	                         	    	            	            	            	            	DA Htr Output V B 	1DAHBVO 	28.0--32.0            	 V     	            	            	            	which are  only obtained while heating up to -60~C; 	            	 	            	   	      
   	                         	    	            	            	            	            	DA Htr Current B 	1DAHBCU  	$\sim2.0$         	A      	            	    	       	 power drops as steady state is reached. 	            	  	            	   	      
 	Total Time	4	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 