Step	Title                    	Time	Command     	Command     	Cmd         	Seq         	Telemetry   	Telemetry   	Expected    	Units 	Telemetry   	Other       	Crit        	Description              	Notes       	RT 	Tlm	Min	SIM   
\# 	                         	Req (m)	Description 	Mnemonic    	EGSE        	Key         	Description 	Mnemonic    	Value       	      	EGSE        	Verifier        	              	                         	            	Con	Fmt	Alt	Pos   
   	 2.17\_V2.0             	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1	Start DEA HK if necessary  	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.1	Load Board 11 DEA HK     	1   	loadDeaBlock	WD00001024  	            	            	 	            	            	      	Check cmdResult == OK 	            	       B 	Load Fullhouse DEA housekeeping	   	   	1or2   	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 225 	            	            	parameter block into slot 4	            	   	   	   	      
1.2	Start DEA Hkp run        	1   	startDEA    	XDZ0000005  	            	            	 	            	            	      	deaHousekeepingData 	            	B            	get FP temp. 	 	  	  1or2 	   	      
 	        	  	  	            	            	 	            	            	      	 	commandEcho 18 	 		    	 	  	 	   	      
2	Switch to tlm fmt 4             	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
2.1	Switch to tlm fmt 4      	2   	            	            	            	            	            	            	            	      	            	            	            	Spacecraft command       	            	Y  	4  	   	      
3	Enable Door Mechanism              	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
3.1	Enable door mech. B      	1   	Door enable B	1MCMDBEN    	            	            	Enable Side B 	1MDBUBON    	ENB         	      	            	            	2            	should be one == enabled               	            	Y   	4  	   	      
3.2	Verify Actuator temps    	10   	            	            	            	            	Door Close Act. T B	1MAHCBT     	$<30$            	C      	            	            	2           	thermistor not sensitive below 30~C   	            	Y 	4   	   	      
   	                         	    	            	            	            	            	Door Open Act. T B	1MAHOBT     	$<30$  	C      	            	            	2          	                         	            	   	4           	   	      
     	                         	                     	            	            	            	            	Act. Housing T B	1OAHBT      	$-32\pm2$      	C      	            	            	2          	                         	            	   	4  	   	      
 	    	   	            	            	            	            	Door Open Act. Tlow	1OAHAT      	$-30\pm2$           	C      	            	            	2           	                         	            	Y  	4  	   	      
3.3	Verify Shaft rotation    	1   	            	            	            	            	Shaft Rotation 	1DACTAT      	$71.5\pm2$            	      	            	            	2         	should be open !         	            	Y   	4  	   	      
3.4	Verify limit switches    	1   	            	            	            	            	Door Open B 	1MEOPBOP    	OPEN   	      	            	            	2          	should be zero==open      	            	Y  	4  	   	      
   	                         	    	            	            	            	            	Door Close B 	1MECLBCL    	NCLO           	      	            	            	2          	should be one==not closed      	            	   	4  	   	      
4	First Heating Cycle                	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
4.1	SOT selects duration  	2.0   	 	    	            	            	 	    	          	      	            	            	  	SOT calls out duration and name of SCS, expectation is 140~s  	    	Y  	4  	   	      
4.2	FOT uplinks SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	FOT uplinks specified SCS into appropriate slot  	    	Y  	4  	   	      
4.3	FOT enables SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	spacecraft command  	    	Y  	4  	   	      
4.4	FOT executes SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	spacecraft command, heating cycle starts  	    	Y  	4  	   	      
   	Close door side B             	1.9   	Door Close On B	1MCDRBON    	            	            	Close Drive On/Off	1MCDRBCL    	ON         	      	            	            	2          	heater on for 140~s         	            	 	  	   	      
   	Turn off Close drive B          	  	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF          	      	            	            	2           	Off command sent twice by SCS with 1s delay.  	            	   	 	   	      
   	Turn off Close drive B          	   	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF          	      	            	            	2            	     	            	   	 	   	      
4.5	Turn off Close drive B          	1   	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF          	      	            	            	2            	FOT has command queued in scratchpad  	            	Y   	4  	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	and ready to be sent immediately       	            	   	   	   	      
5	Verify expected behavior               	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
5.1	Verify Actuator temps    	10   	            	            	            	            	Door Close Act. T B	1MAHCBT      	$\sim66.0$            	C      	            	            	2           	                         	            	Y  	4  	   	      
5.2	Verify Shaft rotation    	1   	            	            	            	            	Shaft Rotation 	1DACTAT      	70.0$\pm5$            	      	            	            	2           	should be open !         	            	Y  	4  	   	      
5.3	Verify limit switches    	1   	            	            	            	            	Door Open B 	1MEOPBOP    	OPEN           	      	            	            	2           	should be zero==open      	            	Y  	4  	   	      
   	                         	    	            	            	            	            	Door Close B 	1MECLBCL    	NCLO           	      	            	            	2           	should be one==not closed      	            	   	  	   	      
6	Monitor Actuator Cooldown    	    	            	            	            	            	            	            	            	      	            	                     	            	                         	            	   	   	   	      
6.1	Monitor actuator temp          	45   	            	            	            	            	Door Close Act. T B	1MAHCBT      	$<30$          	C      	            	            	2          	Wait for actuator to drop below 30~C. 	            	Y   	4  	   	      
7	Decision for next heating cycle          	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
7.1	Does previous cycle need 	2   	            	            	            	            	            	            	            	      	            	            	          	If yes go back to step  \#6, 	            	Y  	4   	   	      
   	repeating ?        	    	            	            	            	            	            	            	            	      	            	            	            	If no proceed to step \#10 	            	  	   	   	      
8	Second Heating Cycle                	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
8.1	SOT selects duration  	2.0   	 	    	            	            	 	    	          	      	            	            	  	SOT calls out duration and name of SCS, expectation is 100~s  	    	Y  	4  	   	      
8.2	FOT uplinks SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	FOT uplinks specified SCS into appropriate slot  	    	Y  	4  	   	      
8.3	FOT enables SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	spacecraft command  	    	Y  	4  	   	      
8.4	FOT executes SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	spacecraft command, heating cycle starts  	    	Y  	4  	   	      
    	Close door side B             	2.1  	Door Close On B On	1MCDRBON    	            	            	Close Drive On/Off	1MCDRBCL    	ON          	      	            	            	2           	heater on for 100~s        	            	  	 	   	      
   	Turn off Close drive B          	  	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF         	      	            	            	2           	Off command sent twice by SCS with 1s delay. 	            	   	 	   	      
   	Turn off Close drive B          	   	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF          	      	            	            	2            	     	            	  	  	   	      
8.5	Turn off Close drive B          	1   	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF          	      	            	            	2            	FOT has command queued in scratchpad  	            	Y   	4  	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	and ready to be sent immediately       	            	   	   	   	      
9	Verify expected behavior               	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
9.1	Verify Actuator temps    	10   	            	            	            	            	Door Close Act. T B	1MAHCBT      	$\sim71.0$            	C      	            	            	2           	                         	            	Y  	4  	   	      
9.2	Verify Shaft rotation    	1   	            	            	            	            	Shaft Rotation 	1DACTAT      	$65\pm5$            	      	            	            	2           	should be $65\pm5$ degrees     	            	Y  	4  	   	      
9.3	Verify limit switches    	1   	            	            	            	            	Door Open B 	1MEOPBOP    	NOPE         	      	            	            	2           	should be one == not open      	            	Y  	4  	   	      
   	                         	    	            	            	            	            	Door Close B 	1MECLBCL    	NCLO           	      	            	            	2           	should be one==not closed      	            	   	  	   	      
10	Monitor Actuator Cooldown    	    	            	            	            	            	            	            	            	      	            	                     	            	                         	            	   	   	   	      
10.1	Monitor actuator temp          	45   	            	            	            	            	Door Close Act. T B	1MAHCBT      	$<30$         	C      	            	            	2            	Wait for actuator to drop below 30~C. 	            	Y   	4  	   	      
11	Decision for next heating cycle               	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
11.1	Does previous cycle need  	2   	            	            	            	            	            	            	            	      	            	            	           	If yes go back to step  \#10, 	            	Y  	 4  	   	      
   	repeating ?       	    	            	            	            	            	            	            	            	      	            	            	            	If no proceed to step \#14 	            	  	   	   	      
12	Third Heating Cycle                	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
12.1	SOT selects duration  	2.0   	 	    	            	            	 	    	          	      	            	            	  	SOT calls out duration and name of SCS, expectation is 135~s  	    	Y  	4  	   	      
12.2	FOT uplinks SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	FOT uplinks specified SCS into appropriate slot  	    	Y  	4  	   	      
12.3	FOT enables SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	spacecraft command  	    	Y  	4  	   	      
12.4	FOT executes SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	spacecraft command, heating cycle starts  	    	Y  	4  	   	      
    	Close door side B             	2.3  	Door Close On B 	1MCDRBON    	            	            	Close Drive On/Off	1MCDRBCL    	ON         	      	            	            	2           	heater on for 135~s         	            	 	  	   	      
   	Turn off Close drive B          	  	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF          	      	            	            	2            	Off command sent twice by SCS with 1s delay.  	            	   	 	   	      
   	Turn off Close drive B          	   	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF          	      	            	            	2            	     	            	   	 	   	      
12.5	Turn off Close drive B          	1   	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF          	      	            	            	2            	FOT has command queued in scratchpad  	            	Y   	4  	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	and ready to be sent immediately       	            	   	   	   	      
13	Verify expected behavior               	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
13.1	Verify Actuator temps    	10   	            	            	            	            	Door Close Act. T B	1MAHCBT      	$\sim85.0$            	C      	            	            	2           	                         	            	Y  	4  	   	      
13.2	Verify Shaft rotation    	2   	            	            	            	            	Shaft Rotation 	1DACTAT      	35$\pm5$           	      	            	            	2           	should be 35$\pm5$ degrees      	            	Y  	4  	   	      
13.3	Verify limit switches    	2   	            	            	            	            	Door Close B 	1MEOPBOP    	NOPE         	      	            	            	2           	should be one == not open      	            	Y  	4  	   	      
   	                         	    	            	            	            	            	Door Close B 	1MECLBCL    	NCLO            	      	            	            	1          	should be one==not closed      	            	   	 	   	      
14	Monitor Actuator Cooldown    	    	            	            	            	            	            	            	            	      	            	                     	            	                         	            	   	   	   	      
14.1	Monitor actuator temp          	30   	            	            	            	            	Door Close Act. T B	1MAHCBT      	$<30$          	C      	            	            	2            	Wait for actuator to drop below 30~C. 	            	Y   	4  	   	      
15 	Decision for next heating cycle               	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
15.1	Is the shaft rotation  	2   	            	            	            	            	            	            	            	      	            	            	           	If no, {\bf GO TO STEP 21, DISABLE THE}  	            	Y  	 4  	   	      
   	 angle < 40 degrees ?     	    	            	            	            	            	            	            	            	      	            	            	            	{\bf ACTUATOR, AND EXIT THIS PROCEDURE !} 	            	 	   	   	      
   	   	    	            	            	            	            	            	            	            	      	            	            	            	If yes proceed to \#18. 	            	 	   	   	      
16	Fourth Heating Cycle                	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
16.1	SOT selects duration  	2.0   	 	    	            	            	 	    	          	      	            	            	  	SOT calls out duration and name of SCS, expectation is 170~s  	    	Y  	4  	   	      
16.2	FOT uplinks SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	FOT uplinks specified SCS into appropriate slot  	    	Y  	4  	   	      
16.3	FOT enables SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	spacecraft command  	    	Y  	4  	   	      
16.4	FOT executes SCS  	2.0   	 	    	            	            	 	    	          	      	            	            	  	spacecraft command, heating cycle starts  	    	Y  	4  	   	      
    	Close door side B             	4.1  	Door Close On B	1MCDRBON    	            	            	Close Drive On/Off	1MCDRBCL    	ON         	      	            	            	2          	heater on for 170~s        	            	  	  	   	      
   	Turn off Close drive B          	  	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF          	      	            	            	2            	off command sent twice   	            	  	  	   	      
   	Turn off Close drive B          	   	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF          	      	            	            	2            	by SCS with 1s delay     	            	   	  	   	      
16.5	Turn off Close drive B          	1   	Door Close Off B   	1MCDRBOF    	            	            	Door Close Drive B   	1MCDRBCL    	OFF          	      	            	            	2            	FOT has command queued in scratchpad  	            	Y   	4  	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	and ready to be sent immediately       	            	   	   	   	      
17	Verify expected behavior               	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
17.1	Verify Actuator temps    	2   	            	            	            	            	Door Close Act. T B	1MAHCBT      	$\sim98.0$            	C      	            	            	2          	                         	            	Y  	4  	   	      
17.2	Verify Shaft rotation    	2   	            	            	            	            	Shaft Rotation 	1DACTAT      	10$\pm5$            	      	            	            	1           	should be 10$\pm5$ degrees      	            	Y  	4  	   	      
17.3	Verify limit switches    	2   	            	            	            	            	Door Open B 	1MEOPBOP    	NOPE         	      	            	            	1           	should be one==not open      	            	Y  	4  	   	      
   	                         	    	            	            	            	            	Door Close B 	1MECLBCL    	NCLO            	      	            	            	1           	should be one==not closed      	            	   	4  	   	      
18 	Monitor Actuator Cooldown    	    	            	            	            	            	            	            	            	      	            	                     	            	                         	            	   	   	   	      
18.1	Monitor actuator temp          	30   	            	            	            	            	Door Close Act. T B	1MAHCBT      	$<30$         	C      	            	            	1            	Wait for actuator to drop below 30~C.  	            	Y   	4  	   	      
19 	Disable drive B          	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
19.1	Disable drive  B          	2   	Door Disable B 	1MCMDBDS    	            	            	Door Enable B   	1MDBUBON    	OFF           	      	            	            	2            	                         	            	Y  	4  	   	      
20	Switch to tlm fmt 1or2             	    	            	            	            	            	            	            	            	      	            	            	                	                         	            	   	   	   	      
20.1	Switch to tlm fmt 1or2      	2   	            	            	            	            	            	            	            	      	            	            	            	Spacecraft command       	            	Y  	1or2  	   	      
 	Total Time	267.4	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 