Step	Title                    	Time	Command     	Command     	Cmd         	Seq         	Telemetry   	Telemetry   	Expected    	Units 	Telemetry   	Other       	Crit        	Description              	Notes       	RT 	Tlm	Min	SIM   
\# 	                         	Req (m)	Description 	Mnemonic    	EGSE        	Key         	Description 	Mnemonic    	Value       	      	EGSE        	Verifier        	              	                         	            	Con	Fmt	Alt	Pos   
   	5.12\_V1.0                	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.0	Verify Initial Temperatures   	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.1 	Verify SIM position 	 1 	   	    	            	            	SIM TT Position 	3TSCPOS   	75624          	      	            	            	1            	should be at ACIS-S 	            	Y  	1or2  	   	      
1.2 	Verify HW Temperatures 	 1 	   	    	            	            	Camera Body T A 	1CBAT    	-62.4          	C      	            	            	2            	should be at -62.4~C 	            	Y  	1or2  	   	      
 	 	  	   	    	            	            	Camera Body T B 	1CBBT    	-59.9          	C      	            	            	2            	should be at -59.9~C 	            	  	  	   	      
  	                         	    	            	            	            	            	Cold Radiator T A 	 1CRAT           	 $\sim-127.9$  	C     	            	 	            	depends on starting point of FP temp. 	            	  	            	   	      
   	                         	    	            	            	            	            	Cold Radiator T B 	 1CRBT           	 $\sim-127.9$  	C     	            	 	            	 	            	  	            	   	      
 	 	  	   	    	            	            	Warm Radiator T A 	1WRAT    	$\sim-82.0$          	C      	            	            	2            	 	            	  	  	   	      
 	 	  	   	    	            	            	Warm Radiator T B 	1WRBT    	$\sim-82.0$          	C      	            	            	2            	 	            	  	  	   	      
1.3	Load Board 11 DEA HK     	1   	loadDeaBlock	WD00001024  	            	            	 	            	            	      	Check cmdResult == OK 	            	       B 	Load Fullhouse DEA housekeeping	   	Y   	1or2   	   	      
   	{\em if necessary} 	    	            	            	            	            	            	            	            	      	commandEcho 225 	            	            	parameter block into slot 4	            	   	   	   	      
1.4	Start DEA Hkp run        	1   	startDEA    	XDZ0000005  	            	            	 	            	            	      	deaHousekeepingData 	            	B            	get FP temp, should be stable and     	 	Y 	  1or2 	   	      
 	{\em if necessary}        	  	  	            	            	 	            	            	      	 	commandEcho 18 	 		$\pm5$~C of desired value. 	 	  	 	   	      
1.5	verify FP temperature    	2   	            	            	            	            	FP Temp 	            	$\sim -119.7$           	C      	deaHousekeepingData 	            	A            	verify FP temp stable at desired temp. 	 	Y  	1or2  	   	      
2.0	Start heating FP to -60.0 C           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
2.1	verify power consumption  	10   	            	            	            	            	DEA Input I 	1DEICACU    	0.60--0.78           	A      	            	            	2            	DEA A Power should be $21\pm3$~W, 	            	Y  	1or2  	   	      
   	                         	    	            	            	            	            	DEA Input V 	1DE28AVO    	27.0-35.0           	V      	            	            	           	current is noisy so an avg. is needed 	            	Y  	1or2            	   	      
2.2	Set warm boot flag off   	1   	DPA Cold Boot	1WRMBTSB(0) 	            	            	            	            	            	      	            	            	            	disable Warm boot if BEP watchdogs	   	Y 	1or2 	   	      
2.3	Upload bakeout patch     	1   	writeBep    	WBBOEN\_ENB 	            	            	 	            	            	      	Check cmdResult == OK 	            	A 	Enable the "enable"      	            	Y  	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 101 	            	            	  	  	   	   	   	      
2.4	Enable the FP BO htr     	1   	changeConfigSetting	WSBAKENABL  	            	            	  	            	            	      	Check cmdResult == OK 	            	A          	enable the FP bakeout heater	If {\it psci} indicates a 	Y  	1or2  	   	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 114 	            	            	  	{\scriptsize SWSTAT\_DEAMAN\_BADCNTLREG}	   	   	   	      
2.5	Set FP temp to -60.0~C     	1   	changeConfigSetting	WSFTNEG\_60     	            	            		            	            	      	Check cmdResult == OK   	            	A         	Set desired FP temp to -60.0~C, 	or {\scriptsize SWSTAT\_DEABOARD\_ERROR,} 	Y  	1or2  	   	      
 	     	   	 	     	            	            		            	            	      	 commandEcho 742  	            	        	FP bakeout htr comes on. 	bakeout enabled failed. 	 	 	   	      
2.6	dump system config.      	0.1   	dumpSysConfig	RS\_0000001 	            	            		            	            	      	Check cmdResult == OK  	            	      B     	get data to verify bakeout enable  	run {\it psci -a -l} to examine 	Y   	1or2  	     	      
   	                         	    	            	            	            	            	            	            	            	      	commandEcho 66  	            	            	  	SysConfig packets. 	   	   	   	      
2.7	wait for FP temp rise     	30   	            	            	            	            	FP Temp 	            	-60.0           	C      	deaHousekeepingData 	            	A            	wait for FP temp to reach -60.0~C  	Time depends on starting T 	P  	1or2  	   	      
   	                         	    	            	            	            	            	Cold Radiator T A 	 1CRAT           	 $\sim-87.0$  	C     	            	 	            	cold radiator temp should increase 	            	  	            	   	      
   	                         	    	            	            	            	            	Cold Radiator T B 	 1CRBT           	 $\sim-87.0$  	C     	            	 	            	 	            	  	            	   	      
3.0	Start heating DH to +25 C           	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
3.1 	Housing Bakeout Enb B    	2   	Housing B.O. Ena B	1HBOBEN     	            	            	DA BO B Enb/Dis 	1DABOBEN    	ENB            	      	            	            	            	                         	            	Y  	1or2   	   	      
3.2	Housing Bakeout On B     	2   	Housing B.O. On B	1HBOBON     	            	            	DA BO B On/Off 	1DABOBON    	ON            	      	            	            	            	                         	            	Y   	1or2  	   	      
   	                         	    	            	            	            	            	DA Htr Output V B 	1DAHBVO 	28.0--34.0            	 V     	            	            	2           	  	            	 	            	   	      
   	                         	    	            	            	            	            	DA Htr Current B  	1DAHBCU  	$\sim2.0$         	A      	            	    	2           	  	            	  	            	   	      
3.3	monitor Camera Body temp  	60   	            	            	            	            	Camera Body T A 	1CBAT     	$>-60$         	C      	            	            	2            	wait for temp to rise    	            	P  	1or2  	   	      
 	 	  	   	    	            	            	Camera Body T B 	1CBBT    	$>-60$         	C      	            	            	2            	significantly above -60.0~C  	            	  	  	   	      
4.0	Verify FP and Camera Body Temp Stable          	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
4.1	wait for stabilization     	480   	            	            	            	            	FP Temp 	            	-60.0           	C      	deaHousekeepingData 	            	A            	verify FP temp stable at -60.0~C  	Time depends on starting T 	P  	1or2  	   	      
 	 	  	   	    	            	            	Camera Body T A 	1CBAT    	$+22.8\pm2$          	C      	            	            	2            	should be at +22.8~C 	            	  	  	   	      
 	 	  	   	    	            	            	Camera Body T B 	1CBBT    	$+17.8\pm2$          	C      	            	            	2            	should be at +17.8~C 	            	  	  	   	      
   	                         	    	            	            	            	            	Cold Radiator T A 	 1CRAT           	 $\sim-50.0$  	C     	            	 	     2  	cold radiator temp should increase 	            	  	            	   	      
   	                         	    	            	            	            	            	Cold Radiator T B 	 1CRBT           	 $\sim-47.5$  	C     	            	 	        2    	 	            	  	            	   	      
 	 	  	   	    	            	            	Warm Radiator T A 	1WRAT    	$\sim-37.6$          	C      	            	            	2            	 	            	  	  	   	      
 	 	  	   	    	            	            	Warm Radiator T B 	1WRBT    	$\sim-37.6$          	C      	            	            	2            	 	            	  	  	   	      
 	Total Time	594.1	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 