Step	Title                    	Time	Command     	Command     	Cmd         	Seq         	Telemetry   	Telemetry   	Expected    	Units 	Telemetry   	Other       	Crit        	Description              	Notes       	RT 	Tlm	Min	SIM   
\# 	                         	Req (s) 	Description 	Mnemonic    	EGSE        	Key         	Description 	Mnemonic    	Value       	      	EGSE        	Verifier        	              	                         	            	Con	Fmt	Alt	Pos   
   	3.4\_V2.0                	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.0	Turn on DH heater        	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
1.1	Enable DH heater side B  	1.025	Housing Htr En B	1HHTRBEN    	            	            	DA B ENB/DIS 	1DAHTBEN    	ENB         	      	            	            	            	                         	            	   	   	   	      
1.2	Turn on DH heater side B 	1.025	Housing Htr On B	1HHTRBON    	            	            	DA B ON/OFF 	1DAHTBON    	ON          	      	            	            	            	                         	            	   	   	   	      
2.0	Turn on DPA Power Supply 	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
2.1	Enable DPA PS A          	1.025	DPA PS A En 	1DPPSAEN    	            	            	            	            	            	      	            	            	            	No verifier before       	            	   	  	   	      
   	                         	    	            	            	            	            	            	            	            	      	            	            	            	power is on              	            	   	   	   	      
2.2	Turn on DPA PS A         	1.025	DPA PS A On 	1DPPSAON    	            	            	DPA A on    	1DPPSA      	ON           	      	            	            	            	                         	            	    	            	   	      
2.3	Enable DPA PS B          	1.025	DPA PS B En 	1DPPSBEN    	            	            	DPA B Enb   	1DPPSBX     	            	      	            	            	            	                         	            	   	  	   	      
2.4	Turn on DPA PS B         	1.025	DPA PS B On 	1DPPSBON    	            	            	DPA B on    	1DPPSB      	ON           	      	            	            	            	                         	            	    	            	   	      
3.0	Turn on DEA, get FP temp 	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
3.1	Enable DEA Power A          	1.025	DEA PS En. A   	1DEPSAEN     	            	            	DEA ENB/DIS A   	1DEPSAX     	E           	      	            	            	            	                         	            	   	  	    	      
3.2	DEA Power Supply A On    	1.025	DEA PS A On  	1DEPSAON     	            	            	DEA ON/OFF A   	1DEPSA      	ON           	      	            	            	            	DEA A Power should be $21\pm3$~W 	            	   	  	    	      
3.3	Start DEA Hkp run        	120 	startDEA    	XDV0000001  	            	            	 	            	            	      	Check cmdResult == 1  	 	            	start DEA Hkp run from slot 0       	 	   	  	    	      
  	     	 	 	  	            	            	            	            	            	      	commandEcho 10 	 	            	        	            	   	   	   	      
4.0	Warm Boot                	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
4.1	set warm boot flag on       	1.025	DPA Warm Boot	1WRMBTSB(1)    	            	            	            	NONE        	            	      	            	            	            	                         	            	   	  	    	      
4.2	Halt BEP                 	1.025	 Halt BEP 	1RSETIRT(0)    	            	            	            	NONE        	            	      	            	            	            	1RSETIRT=1 holds board in reset	       	   	  	    	      
4.3	Restart BEP              	4.100	 Restart BEP 	1RSETIRT(1)    	 	            	 	            	            	      	            	            	            	1RSETIRT=0 releases board 	       	   	  	    	      
4.4	Start DEA Hkp run        	1.025	startDEA    	XDV0000001  	 	            	 	            	            	      	Check cmdResult == 1     	 	            	start DEA Hkp run  from slot 0       	 	   	  	    	      
  	     	 	 	  	            	            	            	            	            	      	commandEcho 10 	 	            	        	            	   	   	   	      
5 	Verify ACIS is in the proper         	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
 	state when TLM is available.         	    	            	            	            	            	            	            	            	      	            	            	            	                         	            	   	   	   	      
5.1	Verify DPA A is on        	   	 	   	            	            	DPA A On    	1DPPSA      	ON           	      	            	            	          	                         	            	  	            	   	      
   	                         	    	            	            	            	            	DPA A Enb   	1DPPSAX     	ENB           	      	            	            	            	                         	            	   	   	   	      
   	                         	    	            	            	            	            	DPA +5V     	1DPP0AVO    	4.9--5.5    	V      	            	            	            	      	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input V 	1DP28AVO    	28.0--34.0    	V      	            	            	            	Expect 12~W for side A, power consumption 	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input I 	1DPICACU    	0.35--0.43       	A      	            	            	           	should be more stable than I or V. 	            	   	   	   	      
5.2	Verify DPA PS B  is on       	   	 	    	            	            	DPA B on    	1DPPSB      	ON           	      	            	            	           	                         	            	   	            	   	      
   	                         	    	            	            	            	            	DPA +5V     	1DPP0BVO    	4.9--5.5           	V      	            	            	            	     	            	   	   	   	      
 	                     	    	            	            	            	            	DPA Input V 	1DP28BVO    	28.0--34.0       	V      	            	            	2            	Expect 9~W for side B, power consumption  	            	   	   	   	      
   	                         	    	            	            	            	            	DPA Input I 	1DPICBCU    	0.26--0.32           	A      	            	            	           	should be more stable than I or V.  	            	   	   	   	      
5.3 	Verify DEA A is On    	    	            	            	            	      	DEA A ENB/DIS	1DEPSAX    	ENB          	     	            	            	  	                         	            	  	   	   	      
   	                         	    	            	            	            	      	DEA A ENB/DIS	1DEPSA    	ON          	     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA +24 V A 	1DEP2AVO    	24.0--26.0          	V     	            	            	 	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA +6 V A  	1DEP0AVO    	5.6--6.7           	V     	            	            	 	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA -6 V A  	1DEN0AVO    	-7.0-- -5.7          	V     	            	            	 	                         	            	   	   	   	      
   	                         	    	            	            	            	       	DEA +15 V A 	1DEP1AVO    	15.0--17.0          	V     	            	            	 	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA -15 V A 	1DEN1AVO     	-17.0-- -15.0         	V     	            	            	 	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA +28 V A 	1DEP3AVO    	>26.0          	V     	            	            	 	                         	            	   	   	   	      
5.4   	Verify DEA B is off                         	    	            	            	            	      	DEA Input I B	1DEICBCU    	<0.2        	A     	            	            	 	  	            	   	   	   	      
   	                         	    	            	            	            	      	DEA +6 V B  	1DEP0BVO    	$0.0\pm0.2$     	V     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA -6 V B  	1DEN0BVO    	$0.0\pm0.2$        	V     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	       	DEA +15 V B 	1DEP1BVO    	$0.0\pm0.2$      	V     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA -15 V B 	1DEN1BVO     	$0.0\pm0.2$   	V     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA +24 V B 	1DEP2BVO    	$0.0\pm0.2$       	V     	            	            	  	                         	            	   	   	   	      
   	                         	    	            	            	            	      	DEA +28 V B 	1DEP3BVO    	$0.0\pm0.2$        	V     	            	            	   	                         	            	   	   	   	      
5.5   	Verify DA Htr A is off    	    	            	            	            	            	DA Htr +28V INPUT A 	1DAHHAVO 	 $0.0\pm0.2$            	V   	            	            	             	  	            	  	            	   	      
   	                         	    	            	            	            	            	DA Htr Output V A 	1DAHAVO 	 $0.0\pm0.2$         	 V     	            	            	             	  	            	 	            	   	      
   	                         	    	            	            	            	            	DA Htr Current A  	1DAHACU  	<0.2        	A      	            	    	             	   	            	  	            	   	      
5.6  	Verify DA Htr B  is on    	    	            	            	            	            	DA Htr +28V INPUT B 	1DAHHBVO 	 28.0--32.0          	V   	            	            	             	values shown are maximum voltage and current	            	  	            	   	      
   	                         	    	            	            	            	            	DA Htr Output V B 	1DAHBVO 	28.0--32.0            	 V     	            	            	            	which are  only obtained while heating up to -60; 	            	 	            	   	      
   	                         	    	            	            	            	            	DA Htr Current B  	1DAHBCU  	$\sim2.0$         	A      	            	    	       	 power drops as steady state is reached. 	            	  	            	   	      
5.7 	Verify BEP A Boot 	 	            	            	            	            	            	            	            	     	Check bepStartupMessage:   	            	  	   	   	    	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	bepTickCounter $< 10$; version =11;	            	 	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	watchdogFlag = 0, patchValidFlag =1         	            	   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	warmbootFlag = 1        	            	   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	Check swHousekeeping messages:	            	   	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	startingBepTickCounter $< 10$;            	            	 	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	endingBepTickCounter=  	            	  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	=startingBepTickCounter+640  	            	  	   	   	      	 	 	 
   	                         	    	            	            	            	            	            	            	            	      	version =11 	            	 	   	   	      	 	 	 
5.8 	Check HW LEDs    	  	            	            	            	      	BEP Select 	1STAT4ST    	0          	     	            	            	 	0 indicates BEP A is selected 	            	  	  	   	      
  	   	    	            	            	            	      	BEP FIFO Not Full 	1STAT6ST    	1          	     	            	            	 	1 means FIFO not full 	            	   	   	   	      
  	   	    	            	            	            	      	BEP FIFO Not Empty 	1STAT7ST    	0          	     	            	            	 	1 means FIFO not empty 	            	   	   	   	      
5.9	Check SW LEDs    	  	            	            	            	      	BEP initialization 	1STAT3ST    	0          	     	            	            	 	0 means BEP SW is running 	            	   	   	   	      
   	   	    	            	            	            	      	Watchdog boot 	1STAT2ST    	1          	     	            	            	 	1 means no watchdog boot 	            	   	   	   	      
   	   	    	            	            	            	      	Science run status	1STAT1ST    	1          	     	            	            	 	1 means science idle 	            	   	   	   	      
   	   	    	            	            	            	      	  	1STAT0ST    	0or1          	     	            	            	 	this bit toggles to indicate BEP is running	            	   	   	   	      
5.10	monitor camera body temp 	 	   	    	            	            	Camera Body T A 	1CBAT    	-60          	C      	            	            	           	survival is -75.5~C, so temp should 	            	  	  	   	      
 	 	  	   	    	            	            	Camera Body T B 	1CBBT    	-60          	C      	            	            	           	be between -75.5 and -60~C 	            	  	  	   	      
 	 	  	   	    	            	            	Warm Radiator T A 	1WRAT    	-84          	C      	            	            	            	Warm radiator temperature will 	            	  	  	   	      
 	 	  	   	    	            	            	Warm Radiator T B 	1WRBT    	-84          	C      	            	            	            	rise as the camera body warms up. 	            	  	  	   	      
5.11	Monitor FP temp    	  	 	     	  	          	FP Temp 	            	 $\sim-120$            	C      	deaHousekeepingData  	            	    	survival is $-130$~C, so temp should  	 	  	 	   	      
  	    	    	 	     	  	          	 	            	           	      	  	            	    	be between -130~C and -120~C 	 	 	  	   	      
 	Total Time	135.375	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 	 